<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML" article-type="research-article">
<front>
<journal-meta>
<journal-id journal-id-type="publisher-id">BJBMS</journal-id>
<journal-title>Bosnian Journal of Basic Medical Sciences</journal-title>
<issn pub-type="ppub">1512-8601</issn>
<issn pub-type="epub">1840-4812</issn>
<publisher>
<publisher-name>Association of Basic Medical Sciences of Federation of Bosnia and Herzegovina</publisher-name>
<publisher-loc>Bosnia</publisher-loc>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">BJBMS-8-193</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Article</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>STUDY OF THE APPLICABILTY OF CONTENT UNIFORMITY AND DISSOLUTION VARIATION TEST ON ROPINIROLE HYDROCHLORIDE TABLETS</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Vranić</surname>
<given-names>Edina</given-names>
</name>
<xref ref-type="aff" rid="aff1">1</xref>
<xref ref-type="corresp" rid="cor1">*</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Uzunović</surname>
<given-names>Alija</given-names>
</name>
<xref ref-type="aff" rid="aff2">2</xref>
</contrib>
</contrib-group>
<aff id="aff1"><label>1</label>Department of Pharmaceutical Technology, Faculty of Pharmacy, University of Saraj evo, Čekaluša 90, 71 000 Sarajevo, Bosnia and Herzegovina</aff>
<aff id="aff2"><label>2</label>Institute for Quality Control of Medicines, Titova 9, 71 000 Sarajevo, Bosnia and Herzegovina</aff>
<author-notes>
<corresp id="cor1">
<label>*</label>Corresponding author
</corresp>
</author-notes>
<pub-date pub-type="ppub">
<year>2008</year>
</pub-date>
<volume>8</volume>
<issue>2</issue>
<fpage>193</fpage>
<lpage>200</lpage>
<permissions>
<copyright-statement>Copyright: © 2008 ABMSFBIH</copyright-statement>
<copyright-year>2008</copyright-year>
</permissions>
<abstract>
<p>When considering single-dose preparations, it is fundamental that the patient receives in his individual dose an amount of drug close to that claimed on the label. Since drug content and content uniformity of single-dose preparations depend on a number of processes associated with their manufacture, it is obviously unrealistic to expect every unit of product to possess exactly the same amount of the active ingredient. For that reason, pharmacopeial standards and specifications have been established to provide limits for permissible variations in the amount of active ingredient of individual single-dose units. The aim of our study was to determine the applicability of content uniformity and dissolution variation test on ropinirole hydrochloride tablets. According to the results obtained, we may conclude that analyzed ropinirole hydrochloride tablets satisfied pharmacopeial requirements concerning content uniformity and dissolution testing. In this case RSD tended to increase with the decrease of the labeled strength. It is obvious from the R<sup>1</sup> value, as well. On the other side, if consider larger number of lots, analyzed by different assay methods and various sample preparation procedures this correlation is less pronounced. This may be a consequence of different assay techniques applied, HPLC, UV-D1 or UV</p>
</abstract>
<kwd-group>
<kwd>ropinirole hydrohloride</kwd>
<kwd>dissolution test</kwd>
<kwd>content uniformity</kwd>
</kwd-group>
</article-meta>
</front>
<body>
<sec id="sec1-1" sec-type="intro">
<title>INTRODUCTION</title>
<p>When considering single-dose preparations, it is fundamental that the patient receives in his individual dose an amount of drug close to that claimed on the label. Since drug content and content uniformity of single-dose preparations depend on a number of processes associated with their manufacture, it is obviously unrealistic to expect every unit of product to possess exactly the same amount of the active ingredient. For that reason, pharmacopeial standards and specifications have been established to provide limits for permissible variations in the amount of active ingredient of individual single-dose units (<xref ref-type="bibr" rid="ref1">1</xref>). Content uniformity is one in a series of tests in a therapeutic product specification that assesses the quality of a batch. Testing for content uniformity helps ensure that the strength of a therapeutic product remains within specified acceptance limits. Recent national and international regulatory and compendial efforts have focused on harmonizing content uniformity testing, with several different approaches under consideration. The differing approaches arise from differing motivations (batch release vs. marketplace testing of a single unit), testing (uniformity of content vs. uniformity of mass), products covered (oral, oral inhalation and nasal drug products), and statistical strategies (<xref ref-type="bibr" rid="ref2">2</xref>). The subject of content uniformity of single-dose units has been considered a lot. However, different methodologies and specifications are still prescribed in different official pharmacopeias like of European Pharmacopeia 6<sup>th</sup> (Eur. Pharm. 6<sup>th</sup>) (<xref ref-type="bibr" rid="ref3">3</xref>) and United States Pharmacopeia 31<sup>st</sup> (USP 31) (<xref ref-type="bibr" rid="ref4">4</xref>). Characterization studies conducted during product development assess safety, efficacy, and quality measures for a therapeutic product. For therapeutic products approved through a regulatory process, safety and efficacy characterization studies are reflected in the approved product label. Quality characterization studies are performed in relation to safety and efficacy studies and are at times associated with specified acceptance criteria. For example, product bioavailability and bioequivalence quality studies are one-time product performance characterization studies that, in the case of bioequivalence, may be assessed using specified criteria and pre-determined pass/fail bioequivalence limits (<xref ref-type="bibr" rid="ref5">5</xref>,<xref ref-type="bibr" rid="ref6">6</xref>). Quality characterization studies provide specifications, defined as a list of tests, references to analytical procedures to evaluate those tests, and appropriate acceptance criteria (<xref ref-type="bibr" rid="ref7">7</xref>).</p>
<p>The aim of our study was to:</p>
<p>
<list list-type="simple">
<list-item><p>- compare content uniformity and dissolution variation test of different tablets, labeled strength 0,25; 0,5; 1; 2 and 5 mg, respectively (different assay techniques applied, HPLC, UV-D1 or UV).</p></list-item>
<list-item><p>- study the applicability of content uniformity and dissolution variation test of ropinirole hydrochloride tablets, labeled strength 0,25; 0,5; 1; 2 and 5 mg, respectively (HPLC assay techniques applied).</p></list-item>
</list>
</p>
</sec>
<sec id="sec1-2">
<title>CURRENT APPROACHES TO CONTENT UNIFORMITY DATA ANALYSIS</title>
<p>Current approaches to content uniformity testing are based on either parametric tolerance intervals or a nonparametric procedure that can be recognized as a nonparametric tolerance interval. Three decisions are needed to assess content uniformity using a tolerance interval approach (<xref ref-type="bibr" rid="ref8">8</xref>). These are:</p>
<p>
<list list-type="simple">
<list-item><p>- acceptable tolerance limits (e.g., 85-115% of label claim);</p></list-item>
<list-item><p>- minimum proportion, p, of the batch that should fall within the limits (e.g., 90% of units in a batch); and</p></list-item>
<list-item><p>- degree of confidence needed to make an accept/reject decision (e.g., 95%).</p></list-item>
</list>
</p>
<p>For <italic>nonparametric</italic> approaches, conformance is determined based on the number of assay values that fall within a specified accept/reject limit, irrespective of the actual values. With parametric tolerance intervals, an accept decision is reached if the test data expressed in terms of the criterion yield an observed tolerance interval that falls entirely within the tolerance limits. Parametric tolerance intervals provide simultaneous direct control on the mean and standard deviation of the batch (Figures <xref ref-type="fig" rid="F1">1</xref> and <xref ref-type="fig" rid="F2">2</xref>). For all combinations of means and standard deviations on or below each curve, at least 90% of the distribution falls within the tolerance limits (<xref ref-type="fig" rid="F1">Figure 1</xref>). The upper curve is for wide tolerance limits, 65-135% of label claim, and thus allows more combinations of means and variances. The lowest curve, with narrow specified tolerance limits of 80-120%, is more restrictive. For all combinations of means and standard deviations on or below each curve, at least a specified portion of the distribution falls within the tolerance limits of 80-120% (<xref ref-type="fig" rid="F2">Figure 2</xref>). The lowest curve is a high coverage probability of 95% and thus allows fewer combinations of means and variances. The upper curve, with lower coverage probability is less restrictive. For <italic>parametric</italic> tolerance interval testing, the general form of the criterion is <italic>Y</italic> ±kS, where <italic>S</italic> is the observed standard deviation, and <italic>k</italic> is a tolerance interval constant that accounts for sample size as well as the population fraction <italic>p</italic> (<xref ref-type="bibr" rid="ref9">9</xref>). For this application, <italic>Y</italic>is the difference between a test mean, X, and a reference mean. The reference mean in content uniformity may be fixed as either the label claim or rubric mean, M, expressed as a percent. The rubric mean can sometimes be greater or less than 100% of label claim, with corresponding changes in tolerance limits. After subtracting the reference mean the tolerance limits are similarly adjusted, e.g., 85%-115% of label claim becomes ±15%. When the tolerance limits are symmetric about zero, as ±15%, the decision to accept the batch can be made using the largest absolute value from the interval; that is, reducing the tolerance interval to a single value, | <italic>Y</italic> |+ kS. Usually, parametric tolerance interval approaches assume normal distribution of the data, possibly following a transformation, such as to log scale. Nonparametric approaches do not assume normal distribution of test data. If the normality assumption is correct (and normality seems reasonable for content uniformity testing), the parametric tolerance interval approach ought to make better use of the data than approaches based on counts of values falling within specified intervals (<xref ref-type="bibr" rid="ref10">10</xref>). All current content uniformity tests, whether non-parametric or parametric, use a two tier approach with fixed numbers of units allowed for testing in each tier. If results are sufficiently positive in the first stage (tier) of testing, then the study stops. If insufficiently positive, the study may continue to the second stage. In the language of clinical trials, the initial tiers of multiple-tier testing are interim analyses. When two tiers are used, the calculation of the actual type I (false positive) error rate for the full two-tier design needs to take into account both tiers. For example, a 5% test at each tier will have a combined type I error rate exceeding 5% (<xref ref-type="bibr" rid="ref11">11</xref>). For nonparametric tolerance intervals, the method of Simon (<xref ref-type="bibr" rid="ref12">12</xref>) can be adopted for two-tier designs. Hauck and Shaikh (<xref ref-type="bibr" rid="ref13">13</xref>) developed a method for parametric tolerance intervals and designs of one or more tiers.</p>
<fig id="F1">
<label>FIGURE 1</label>
<caption>
<p>Combination of means and standard deviations corresponding to 90% coverage (p) (<xref ref-type="bibr" rid="ref8">8</xref>)</p>
</caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="bjbms-8-193-g001.jpg"/>
</fig>
<fig id="F2">
<label>FIGURE 2</label>
<caption>
<p>Means and standard deviations in the batch corresponding to 80-120% tolerance limits (<xref ref-type="bibr" rid="ref8">8</xref>)</p>
</caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="bjbms-8-193-g002.jpg"/>
</fig>
</sec>
<sec id="sec1-3">
<title>CURRENT APPROACHES FÜR DISSOLUTION TESTING DATA ANALYSIS</title>
<p>Acceptance criteria for the dissolution procedure can either be a limit (the <italic>Q</italic> value) or a range (upper and lower percent dissolved at a specified time). Although acceptance criteria may be based on an <italic>in vitro-in vivo</italic> correlation (<xref ref-type="bibr" rid="ref14">14</xref>), setting acceptance criteria frequently lacks a formal approach for most dosage forms (<xref ref-type="bibr" rid="ref15">15</xref>). USP and other pharmacopeas currently mostly use nonparametric approach for both content uniformity and dissolution testing. For content uniformity testing, Katori et al. (<xref ref-type="bibr" rid="ref1">1</xref>) proposed replacing the current USP approach (test by attributes) with a parametric approach (test by variables), using a tolerance interval (<xref ref-type="bibr" rid="ref16">16</xref>). Moving from a nonparametric to a parametric approach depends in part on whether a specific distribution, such as the normal, can be assumed. The normal distribution can be a reasonable assumption for content uniformity testing but not necessarily for dissolution testing. Normal distribution of dissolution data may be unlikely due to the boundary of 100% dissolved—with values sometimes greater than 100% given variability in assay and content. The 100% boundary forces non-symmetry and hence non-normality of distribution. Although data transformation may help, one solution to this issue would be to choose the time at which dissolution is measured to achieve values that are acceptably below 100%. In contrast to use of a parametric tolerance interval approach for content uniformity testing, Katori <italic>et al</italic>. (<xref ref-type="bibr" rid="ref17">17</xref>) proposed a parametric confidence interval approach for dissolution testing (<xref ref-type="table" rid="T1">Table I</xref>). Both confidence and tolerance intervals estimate the characteristics of a distribution. Confidence intervals assess the precision of estimates of single quantity (e.g., mean, variance). For example, a 95% confidence interval for a mean consists of all values within ±2 standard errors of the estimated mean; the more precise the estimate, the narrower the confidence interval. In contrast, tolerance intervals describe ranges of specified coverage for a distribution of values (<xref ref-type="bibr" rid="ref16">16</xref>); for example, at least 80% of dissolution values for a product fall within a specified range with some specified level of confidence. A choice between the two approaches is based on what quantity (or quantities) best characterizes the distribution for the problem of interest. Characterizing the distribution solely by the mean and its confidence interval is insufficient— they are essentially uninformative as to the width of the distribution. In order to consider variability as well, standard deviation controls could be established.</p>
<table-wrap id="T1">
<label>TABLE 1</label>
<caption>
<p>Content uniformity of different tablets (30 lots), labeled strength 0,25; 0,5; 1; 2 and 5 mg, (different assay techniques applied, HPLC, UV-D1 or UV) expressed as % of the declared content</p>
</caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="bjbms-8-193-g003.jpg"/>
</table-wrap>
</sec>
<sec id="sec1-4" sec-type="materials|methods">
<title>MATERIALS AND METHODS</title>
<sec id="sec2-1">
<title/>
<sec id="sec3-1">
<title>Materials</title>
<p>For this study, ropinirole hydrochloride tablets were used; labels claim 0,25; 0,5; 1; 2 and 5 mg, respectively.</p>
</sec>
<sec id="sec3-2">
<title>Methods</title>
<p>Content uniformity analysis</p>
<p>For each individual lot, 10 units were sampled. Measurements were done by the individual manufacturer. The assay methods used were HPLC and UV absorption. The mean and SD of drug content, formulation weight and concentration of active ingredient (w/w%) were calculated for each group of 10 units in a single lot.</p>
<p>Units were weighed and assayed in succession. The concentration of the active ingredient was calculated by dividing drug content by formulation weight that included the weight of coating.</p>
<p>Dissolution profile analysis</p>
<p>For each individual lot, 6 units were sampled. Dissolution samples were collected for analysis and replaced with an equal volume of fresh dissolution fluid to maintain a constant total volume. The assay methods used were HPLC and UV absorption.</p>
</sec>
</sec>
</sec>
<sec id="sec1-5" sec-type="results|discussion">
<title>RESULTS AND DISCUSSION</title>
<p>The content and dissolution testing values are accessible only through chemical analysis subject to measurement errors. As the purpose is to calculate tolerance interval for the true active content, the standard deviation and relative standard deviation should stand for the variability of the dosage units. In the measurements, however, there are two sources of variation: variability of the dosage units (non-homogeneity) and the measurement (analytical) error.</p>
<sec id="sec2-2">
<title/>
<sec id="sec3-3">
<title>Relationship between labeled strength and content uniformity</title>
<p>The results of our content uniformity analysis of different tablets (30 lots), labeled strength 0,25; 0,5; 1; 2 and 5 mg are summarized in <xref ref-type="table" rid="T1">Table 1</xref> and <xref ref-type="fig" rid="F3">Figure 3</xref>. The results of content uniformity analysis of ropinirole hydrochloride tablets (1 lot, 5 different label strengths, HPLC assay method) are summarized in <xref ref-type="table" rid="T2">Table 2</xref> and <xref ref-type="fig" rid="F2">Figure 2</xref>.</p>
<table-wrap id="T2">
<label>TABLE 2</label>
<caption>
<p>Content uniformity of ropinirole hydrochloride for five different label claims expressed as % of declared content</p>
</caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="bjbms-8-193-g004.jpg"/>
</table-wrap>
<fig id="F3">
<label>FIGURE 3</label>
<caption>
<p>Relation between declared content of different tablets (mg) and RSD of content uniformity (30 lots)</p>
</caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="bjbms-8-193-g005.jpg"/>
</fig>
</sec>
<sec id="sec3-4">
<title>Relationship between labeled strength and percent ofdrug dissolved</title>
<p>The results of our dissolution test analysis of ropinirole hydrochloride tablets (60 lots) are summarized in <xref ref-type="table" rid="T3">Table 3</xref> and <xref ref-type="fig" rid="F5">Figure 5</xref>.</p>
<fig id="F4">
<label>FIGURE 4</label>
<caption>
<p>Relation between declared content of ropinirole hydrochloride (mg) for five different label strengths and RSD of content uniformity</p>
</caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="bjbms-8-193-g006.jpg"/>
</fig>
<table-wrap id="T3">
<label>TABLE 3</label>
<caption>
<p>Dissolution test analysis of different tablets (60 lots), labeled strength 0,25; 0,5; 1; 2 and 5 mg, (different assay techniques applied, HPLC, UV-D1 or UV) expressed as % of drug dissolved</p>
</caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="bjbms-8-193-g007.jpg"/>
</table-wrap>
<fig id="F5">
<label>FIGURE 5</label>
<caption>
<p>Relation between declared content of different tablets (mg) and RSD of drug dissolved (60 lots)</p>
</caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="bjbms-8-193-g008.jpg"/>
</fig>
<p>The results for dissolution testing of ropinirole hydrochloride tablets (1 lot, 5 different label strengths, HPLC assay method) are summarized in <xref ref-type="table" rid="T4">Table 4</xref> and <xref ref-type="fig" rid="F6">Figure 6</xref>.</p>
<table-wrap id="T4">
<label>TABLE 4</label>
<caption>
<p>Dissolution test analysis of different tablets (60 lots), labeled strength 0,25; 0,5; 1; 2 and 5 mg, (different assay techniques applied, HPLC, UV-D1 or UV) expressed as % of drug dissolved</p>
</caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="bjbms-8-193-g009.jpg"/>
</table-wrap>
<fig id="F6">
<label>FIGURE 6</label>
<caption>
<p>Relation between declared content of ropinirole hydrochloride (mg) for five different label strengths and RSD of drug dissolved</p>
</caption>
<graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="bjbms-8-193-g010.jpg"/>
</fig>
<p>The content uniformity and dissolution testing of a formulation is represented by intra-lot variation (RSD). In this case RSD tended to increase with the decrease of the labeled strength. It is obvious from the R<sup>2</sup> value, as well. On the other side, if we take into consideration larger number of lots, analyzed by different assay methods and different sample preparation procedures this correlation is less pronounced. This can be the consequence of different assay techniques applied, HPLC, UV-D1 or UV.</p>
</sec>
</sec>
</sec>
<sec id="sec1-6" sec-type="conclusion">
<title>CONCLUSION</title>
<p>
<list list-type="simple">
<list-item><p>◊According to the results obtained, we may conclude that the analyzed ropinirole hydrochloride tablets from satisfied pharmacopeial requirements concerning content uniformity and dissolution testing</p></list-item>
<list-item><p>◊In this case, RSD tended to increase with the decrease of the labeled strength. It is obvious from the R<sup>2</sup> value, as well.</p></list-item>
<list-item><p>◊On the other side, if we take into consideration larger number of lots, analyzed by different assay methods and different sample preparation procedures this correlation is less pronounced. This can be the consequence of different assay techniques applied, HPLC, UV-D1 or UV.</p></list-item>
</list>
</p>
</sec>
</body>
<back>
<ref-list>
<title>REFERENCES</title>
<ref id="ref1">
<label>1</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Martins</surname>
<given-names>J.M</given-names>
</name>
<name>
<surname>Farinha</surname>
<given-names>A</given-names>
</name>
</person-group>
<article-title>Uniformity of dosage units—comparative study of methods and specifications between Eur. Pharm. 3rd and USP 23</article-title>
<source>J. Pharm. Biomed. Anal</source>
<year>1998</year>
<volume>18</volume>
<fpage>487</fpage>
<lpage>495</lpage>
</element-citation>
</ref>
<ref id="ref2">
<label>2</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Williams</surname>
<given-names>R.L</given-names>
</name>
<name>
<surname>Adams</surname>
<given-names>W.P</given-names>
</name>
<name>
<surname>Poochikian</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Hauck</surname>
<given-names>W.W</given-names>
</name>
</person-group>
<article-title>Content uniformity and dose uniformity: current approaches, statistical analyses, and presentation of an alternative approach, with special reference to oral inhalation and nasal drug products</article-title>
<source>Pharm. Res</source>
<year>2002</year>
<volume>19</volume>
<issue>4</issue>
<fpage>359</fpage>
<lpage>366</lpage>
</element-citation>
</ref>
<ref id="ref3">
<label>3</label>
<element-citation citation-type="journal">
<collab>European Pharmacopoeia 6<sup>th</sup> Edition</collab>
<source>European Department for the Quality of Medicines Council of Europe, September 2007, Strasbourg</source>
</element-citation>
</ref>
<ref id="ref4">
<label>4</label>
<element-citation citation-type="journal">
<collab>U.S. Pharmacopeia 31<sup>st</sup> rev</collab>
<source>U. S. Pharmacopeial Convention Rockville MD</source>
<year>2007</year>
</element-citation>
</ref>
<ref id="ref5">
<label>5</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Williams</surname>
<given-names>R. L</given-names>
</name>
<name>
<surname>Adams</surname>
<given-names>W</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>M.-L</given-names>
</name>
<name>
<surname>Hare</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Hussain</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Lesko</surname>
<given-names>L</given-names>
</name>
<name>
<surname>Patnaik</surname>
<given-names>R</given-names>
</name>
<collab>Shah V and FDA Biopharmaceutics Coordinating Committee</collab>
</person-group>
<article-title>Where are we now and where do we go next in terms of the scientific basis for regulation on bioavailability and bioequivalence?</article-title>
<source>Eur. J. Drug Metab. Pharmacokinet</source>
<year>2000</year>
<volume>25</volume>
<fpage>712</fpage>
</element-citation>
</ref>
<ref id="ref6">
<label>6</label>
<element-citation citation-type="web">
<collab>U.S Department of Health and Human Services (DHHS) Food and Drug Administration (FDA), Center for Drug Evaluation and Research (CDER)</collab>
<source>Guidance for Industry: Bioavailability and Bioequivalence Studies for Orally Administered Drug Products - General Considerations</source>
<year>2000</year>
<month>October</month>
<access-date>[accessed 20.09.2007]</access-date>
<comment><uri>http://www.fda.gov/cder/guidance/index.htm</uri></comment>
</element-citation>
</ref>
<ref id="ref7">
<label>7</label>
<element-citation citation-type="journal">
<collab>International Conference on Harmonisation</collab>
<article-title>Draft Guidance on Specifications: Test procedures and acceptance criteria for new drug substances and new drug products: Chemical substances</article-title>
<source>Fed. Regist</source>
<year>1997</year>
<volume>62</volume>
<fpage>62890</fpage>
<lpage>62910</lpage>
</element-citation>
</ref>
<ref id="ref8">
<label>8</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Williams</surname>
<given-names>R.L</given-names>
</name>
<name>
<surname>Adams</surname>
<given-names>W.P</given-names>
</name>
<name>
<surname>Poochikian</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Hauck</surname>
<given-names>W.W</given-names>
</name>
</person-group>
<article-title>Content uniformity and dose uniformity: Current approaches, statistical analyses, and presentation of an alternative approach, with special reference to oral inhalation and nasal drug products</article-title>
<source>Pharm. Res</source>
<year>2002</year>
<volume>19</volume>
<issue>4</issue>
<fpage>359</fpage>
<lpage>366</lpage>
</element-citation>
</ref>
<ref id="ref9">
<label>9</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Weissberg</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Beatty</surname>
<given-names>G.H</given-names>
</name>
</person-group>
<article-title>Tables for tolerance-limit factors for normal distributions</article-title>
<source>Technometrics</source>
<year>1960</year>
<volume>2</volume>
<fpage>483</fpage>
<lpage>500</lpage>
<comment>erratum. Technometrics 1961 3 576-577</comment>
</element-citation>
</ref>
<ref id="ref10">
<label>10</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Esinhart</surname>
<given-names>J. D</given-names>
</name>
<name>
<surname>Chinchilli</surname>
<given-names>V</given-names>
</name>
</person-group>
<article-title>M. Sample size considerations for assessing individual bioequivalence based on the method of tolerance intervals</article-title>
<source>Int. J. Clin. Pharmacol. Ther</source>
<year>1994</year>
<volume>32</volume>
<fpage>26</fpage>
<lpage>32</lpage>
</element-citation>
</ref>
<ref id="ref11">
<label>11</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>McPherson</surname>
<given-names>K</given-names>
</name>
</person-group>
<article-title>Statistics: The problem of examining accumulating data more than once</article-title>
<source>N. Engl. J. Med</source>
<year>1974</year>
<volume>290</volume>
<fpage>501</fpage>
<lpage>502</lpage>
</element-citation>
</ref>
<ref id="ref12">
<label>12</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Simon</surname>
<given-names>R</given-names>
</name>
</person-group>
<article-title>Optimal two-stage designs for Phase II clinical trials</article-title>
<source>Control. Clin. Trials</source>
<year>1989</year>
<volume>10</volume>
<fpage>1</fpage>
<lpage>10</lpage>
</element-citation>
</ref>
<ref id="ref13">
<label>13</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hauck</surname>
<given-names>W. W</given-names>
</name>
<name>
<surname>Shaikh</surname>
<given-names>R</given-names>
</name>
</person-group>
<article-title>Sample sizes for batch acceptance from single and multi-stage designs using two-sided normal tolerance intervals with specified content</article-title>
<source>J. Biopharm. Stat</source>
<year>2001</year>
<volume>11</volume>
<issue>4</issue>
<fpage>335</fpage>
<lpage>346</lpage>
</element-citation>
</ref>
<ref id="ref14">
<label>14</label>
<element-citation citation-type="book">
<collab>U.S. Food and Drug Administration Center for Drug Evaluation and Research</collab>
<article-title>Guidance for Industry: Extended-Release Oral Dosage Forms Development Evaluation and Application of In-Vitro/In Vivo Correlations Office of Training and Communications Division of Communications Management</article-title>
<source>Drug Information Branch HFD-210</source>
<year>1997</year>
<publisher-loc>Rockville MD</publisher-loc>
</element-citation>
</ref>
<ref id="ref15">
<label>15</label>
<element-citation citation-type="journal">
<collab>U.S. Food and Drug Administration Center for Drug Evaluation and Research</collab>
<article-title>Guidance for Industry: Dissolution Testing of Immediate-Release Solid Oral Dosage Forms Office of Training and Communications Division of Communications Management</article-title>
<source>Drug Information Branch HFD-210</source>
<year>1997</year>
<publisher-loc>Rockville MD</publisher-loc>
</element-citation>
</ref>
<ref id="ref16">
<label>16</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Katori</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Kaniwa</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Aoyagi</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Kojima</surname>
<given-names>S</given-names>
</name>
</person-group>
<article-title>A new acceptance sampling plan for the official dissolution test</article-title>
<source>Japanese Pharm. Forum</source>
<year>1998</year>
<volume>7</volume>
<fpage>166</fpage>
<lpage>173</lpage>
</element-citation>
</ref>
<ref id="ref17">
<label>17</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Katori</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Aoyagi</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Kojima</surname>
<given-names>S</given-names>
</name>
</person-group>
<article-title>A proposal for revision of the content uniformity test and weight variation test. Stimuli to the revision process</article-title>
<source>Pharm. Forum</source>
<year>1997</year>
<volume>23</volume>
<fpage>5325</fpage>
<lpage>5333</lpage>
</element-citation>
</ref>
</ref-list>
</back>
</article>