﻿<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="research-article" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML">
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">Biomol Biomed</journal-id>
<journal-title>Biomolecules and Biomedicine</journal-title>
<issn pub-type="ppub">2831-0896</issn>
<issn pub-type="epub">2831-090X</issn>
<publisher>
<publisher-name>Association of Basic Medical Sciences of Federation of Bosnia and Herzegovina</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">BB-23-894</article-id>
<article-id pub-id-type="doi">10.17305/bb.2023.9085</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Research article</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Changes of placental three-dimensional power Doppler ultrasonography in third trimester among hypertensive disorders complicating pregnancy</article-title>
</title-group>
<contrib-group>
<contrib  contrib-type="author">
<name>
<surname>Liu</surname>
<given-names>Yingying</given-names>
</name>
<uri content-type="orcid">https://orcid.org/0000-0002-2791-2080</uri>
<xref rid="aff1" ref-type="aff">1</xref>
<xref rid="cor1" ref-type="corresp">&#x002A;</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Gao</surname>
<given-names>Ximei</given-names>
</name>
<uri content-type="orcid">https://orcid.org/0009-0005-5892-2926</uri>
<xref rid="aff2" ref-type="aff">2</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Shi</surname>
<given-names>Dandan</given-names>
</name>
<uri content-type="orcid">https://orcid.org/0009-0004-1833-9210</uri>
<xref rid="aff1" ref-type="aff">1</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Wang</surname>
<given-names>Yong</given-names>
</name>
<uri content-type="orcid">https://orcid.org/0000-0002-5669-0819</uri>
<xref rid="aff1" ref-type="aff">1</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Qi</surname>
<given-names>Xinying</given-names>
</name>
<uri content-type="orcid">https://orcid.org/0009-0002-3836-9711</uri>
<xref rid="aff1" ref-type="aff">1</xref>
</contrib>
<contrib contrib-type="author">
<name>
<surname>Wang</surname>
<given-names>Na</given-names>
</name>
<uri content-type="orcid">https://orcid.org/0000-0003-3903-3929</uri>
<xref rid="aff1" ref-type="aff">1</xref>
</contrib>
</contrib-group>
<aff id="aff1"><label>1</label>Department of Obstetrics, Cangzhou Central Hospital, Cangzhou, China</aff>
<aff id="aff2"><label>2</label>Medical Department, Cangzhou Central Hospital, Cangzhou, China</aff>
<author-notes>
<corresp id="cor1"><label>&#x002A;</label>Correspondence to Yingying Liu: <email xlink:href="mailto:liuying.yingabc@163.com">liuying.yingabc@163.com</email></corresp>
</author-notes>
<pub-date pub-type="ppub">
<day>1</day>
<month>10</month>
<year>2023</year>
</pub-date>
<pub-date pub-type="epub">
<day>1</day>
<month>10</month>
<year>2023</year>
</pub-date>
<volume>23</volume>
<issue>5</issue>
<fpage>894</fpage>
<lpage>901</lpage>
<history>
<date date-type="received">
<day>25</day>
<month>3</month>
<year>2023</year>
</date>
<date date-type="rev-recd">
<day>28</day>
<month>4</month>
<year>2023</year>
</date>
<date date-type="accepted">
<day>17</day>
<month>5</month>
<year>2023</year>
</date>
</history>
<permissions>
<copyright-statement>&#x00A9; 2023 Liu et al.</copyright-statement>
<copyright-year>2023</copyright-year>
<license license-type="standard"><p>This article is available under a Creative Commons License (Attribution 4.0 International, as described at <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link>).</p>
</license>
</permissions>
<abstract>
<p>Hypertensive disorders complicating pregnancy (HDCP) represent a systemic condition specific to pregnant women. Three-dimensional (3D) power Doppler ultrasonography is a technique that utilizes erythrocyte density, scattered intensity, or energy distribution in the bloodstream for imaging purposes. This study aimed to compare the changes in 3D power Doppler ultrasonography parameters in late pregnancy between patients with HDCP and those without HDCP, and to evaluate the predictive value of these parameters for pregnancy outcomes in patients with HDCP. The study included 160 pregnant women diagnosed with HDCP and 100 pregnant women without HDCP, who served as the control group. 3D power Doppler ultrasonography was performed, and the values of the vascularization index (VI), flow index (FI), and vascularization flow index (VFI) were measured. In the HDCP group, the VI, FI, and VFI were all lower than those observed in patients without HDCP. In HDCP patients with positive outcomes, these three parameters were higher than those recorded in patients with negative outcomes. The area under the predicted curve (AUC) for VI, FI, VFI, and the combination of these three parameters were 0.69, 0.63, 0.66, and 0.75, respectively. The parameters of 3D power Doppler ultrasonography can reflect the perfusion status of the placenta and predict the outcome of pregnancy in patients with HDCP. By monitoring these relevant hemodynamic parameters, valuable information can be provided for the clinical diagnosis, objective evaluation, and treatment of HDCP.</p>
</abstract>
<kwd-group>
<kwd>3D power Doppler ultrasonography</kwd>
<kwd>hypertensive disorders complicating pregnancy (HDCP)</kwd>
<kwd>flow index (FI)</kwd>
<kwd>vascularization index (VI)</kwd>
<kwd>vascularization flow index (VFI)</kwd>
</kwd-group>
</article-meta>
</front>
<body>
<sec id="sec1"><title>Introduction</title>
<p>Hypertensive disorders complicating pregnancy (HDCP) is a systemic condition specific to mothers during pregnancy [<xref rid="ref1" ref-type="bibr">1</xref>]. The prevalence of HDCP in China was 10.32% [<xref rid="ref2" ref-type="bibr">2</xref>]. HDCP is clinically characterized by edema, hypertension, and proteinuria [<xref rid="ref3" ref-type="bibr">3</xref>]. Severe HDCP is associated with headache and blurred vision, and may even lead to convulsions and coma [<xref rid="ref4" ref-type="bibr">4</xref>]. HDCP, along with other pregnancy-related cardiovascular system disorders, poses a serious threat to maternal and fetal health [<xref rid="ref5" ref-type="bibr">5</xref>]. Increased systemic vascular resistance in the mother impairs blood flow to many organs and can lead to serious complications [<xref rid="ref6" ref-type="bibr">6</xref>]. If not properly treated, it can cause severe harm and even lead to the death of the pregnant woman and fetus. The etiology of HDCP has not been fully understood [<xref rid="ref7" ref-type="bibr">7</xref>]. Treatment of hypertension in pregnancy is limited, so prevention and prediction of hypertension in pregnancy is particularly important [<xref rid="ref8" ref-type="bibr">8</xref>].</p>
<p>Three-dimensional (3D) power Doppler ultrasonography is a technique that uses erythrocyte density, scattered intensity, or energy distribution in the bloodstream for imaging [<xref rid="ref9" ref-type="bibr">9</xref>]. The technique is relatively simple and safe because it is noninvasive and does not require radiation exposure [<xref rid="ref10" ref-type="bibr">10</xref>]. 3D power Doppler ultrasonography provides a qualitative assessment of vessel type and distribution characteristics [<xref rid="ref11" ref-type="bibr">11</xref>]. It is possible to use the sensitivity of this method for low velocity blood flow and analyze blood flow and resistance conditions in the placenta [<xref rid="ref12" ref-type="bibr">12</xref>]. It has been demonstrated that 3D power Doppler ultrasonography can quantify placental perfusion in the anterior wall and provide a quantitative assessment of placental perfusion for the diagnosis of HDCP [<xref rid="ref13" ref-type="bibr">13</xref>]. However, specific changes in 3D power Doppler ultrasonography parameters in patients with HDCP in late pregnancy and their association with pregnancy outcome in HDCP patients have not yet been reported. In this study, we compared the changes in 3D power Doppler ultrasonography parameters during late pregnancy in HDCP patients and non-HDCP pregnant women and evaluated the predictive value of these parameters for pregnancy outcome in HDCP patients.</p>
</sec>
<sec id="sec2"><title>Materials and methods</title>
<sec id="sec2a"><title>Participants</title>
<p>In this study, 160 pregnant women with HDCP were included, whereas 100 pregnant women without HDCP served as the control group. Both groups were followed until the end of their pregnancies. All participants registered prenatally in our obstetrics department, delivered at our hospital, and signed an informed consent form.</p>
<p>The diagnostic criteria for HDCP were in accordance with the 2013 American College of Obstetricians and Gynecologists (ACOG) guidelines for hypertension in pregnancy, including screening and exclusion criteria.</p>
<p>The diagnostic criteria for preeclampsia (PE) were: after 20 weeks of gestation, if normal previous blood pressure present, a systolic blood pressure (SBP) of &#x2265; 140 mmHg measured at four-h intervals or a diastolic blood pressure (DBP) of &#x2265; 90 mmHg; 24-h urine protein &#x2265; 300 mg (or estimated by collecting urine for a limited time) or urine protein/creatinine &#x2265; 0.3; without present proteinuria but present liver dysfunction, pulmonary edema, renal dysfunction, thrombocytopenia, cerebral or visual disturbances.</p>
<p>The diagnostic criteria for severe PE were, based on PE, accompanied by any of the following symptoms: DBP &#x2265; 110 mmHg or SBP &#x2265; 160 mmHg (interval four hours, without prior use of antihypertensive medication); platelets &#x003C; 100.000/&#x00B5;L; abnormal liver function (elevated transaminases, persistent severe pain in the right upper quadrant or below the diaphragm); progressive renal dysfunction; pulmonary edema; new brain damage and visual disturbances.</p>
<p>The inclusion criteria for HDCP patients were: HDCP pregnant women diagnosed in the third trimester according to the above diagnostic criteria (HDCP patients were included in the third trimester, but the first diagnosis was not limited to the third trimester); age over 18 years; singleton pregnancy.</p>
<p>Exclusion criteria for HDCP patients were: inadequate localization of the placenta, including the anterior and posterior placentas; hypertension before pregnancy; multiple pregnancy; diabetes, cerebrovascular, and severe hepatic and renal insufficiency; concomitant acute and chronic injuries, infections, and rheumatism, rheumatoid, and other immune system-related diseases.</p>
<p>Inclusion criteria for pregnant women without HDCP were: pregnant women in the third trimester; age over 18 years; singleton pregnancy; without HDCP.</p>
<p>The exclusion criteria for pregnant women without HDCP were: Pre-pregnancy hypertension; multiple pregnancy; diabetes, cerebrovascular and severe hepatic and renal insufficiency; concomitant acute and chronic injuries, infections and rheumatism, rheumatoid and other immune system-related diseases.</p>
</sec>
<sec id="sec2b"><title>3D power Doppler ultrasonography</title>
<p>A Voluson E8 (GE Medical Systems, Milwaukee, WI, USA) ultrasound system was used. In addition to routine ultrasound, the placental 3D power Doppler was performed in all women. The five spherical sampling sites in each placenta were as follows: one central, two peripheral at opposite sides, and one between the central site and each peripheral site. The peripheral sampling spheres were always positioned to maintain a minimum distance of approximately 4 mm between the insonated region and the chorionic and basal plates. Maximum sensitivity was ensured with the following settings: pulse repetition frequency 0.6 kHz; wall motion filter low 1; frequency medium; dynamic 3; balance 4150; smooth 4/5; ensemble 11; line density 8; power Doppler map 4; artifact suppression off; power Doppler line filter off; quality high. The placenta was examined with a constant volume and the same 25-degree sector angle. The spheres were kept away from the spiral arteries and placed near the basal and/or chorionic plate. The 3D glass body render mode was used, in which the color and gray-scale information was processed and combined to form a 3D image. Vascularization indices were determined using the virtual organ computer-aided analysis (VOCAL) program. Manual mode was set, and the five spherical regions of interest in each placenta were manually circled by rotating 30 degrees six times, respectively. The placenta was examined with a constant volume and the same 25-degree sector angle. The spheres were kept away from the spiral arteries and placed near the basal and/or chorionic plate. The volume of spheres did not contain vessels of the basal and chorionic plates and was kept constant. A histogram automatically displayed the vascularization indices. The 3D volume was formed using basic units called voxels. The voxel contains all the information about the grayscale and color, according to an intensity scale ranging from zero to 100. The vascularization indices were as follows: the vascularization index (VI) refers to the ratio of color voxel to total voxel and indicates the number of vessels that could be detected within the placental volume; the flow index (FI) refers to the weighted color voxel divided by the ratio of total color voxels and provides an amplitude value for the color signal that indirectly estimates blood flow in the placenta during a 3D sweep; the vascularization flow index (VFI) refers to the weighted ratio of color voxels to total voxels, indicating a combination of vascularity and blood flow. The representative spherical contour of the placenta measured by 3D power Doppler ultrasonography and the output of vocal analysis is shown in <xref ref-type="fig" rid="fS1">Figure S1</xref>.</p>
</sec>
<sec id="sec2c"><title>Ethical statement</title>
<p>The study was approved by the ethics committee of Cangzhou Central Hospital (CZ.9240.v67).</p>
<table-wrap id="TB1">
<label>Table 1</label>
<caption>
<p>Demographic and clinical characteristics of pregnant women with HDCP and without HDCP (control)</p></caption>
<table frame="hsides" rules="groups">
<colgroup>
<col span="1" align="left"/>
<col span="2" align="left"/>
<col span="3" align="left"/>
<col span="4" align="left"/>
</colgroup>
<thead>
<tr valign="bottom">
<th><bold>Characteristics</bold></th>
<th><bold>Control (<italic>n</italic> &#x2550; 100)</bold></th>
<th><bold>HDCP (<italic>n</italic> &#x2550; 160)</bold></th>
<th><bold><italic>p</italic> value</bold></th>
</tr>
</thead>
<tbody>
<tr valign="top">
<td>Maternal age (years)</td>
<td>29.4 &#x00B1; 3.8</td>
<td>30.1 &#x00B1; 4.2</td>
<td>0.195</td>
</tr>
<tr valign="top">
<td>Gestational weeks at admission</td>
<td>34.8 &#x00B1; 3.9</td>
<td>35.2 &#x00B1; 3.6</td>
<td>0.251</td>
</tr>
<tr valign="top">
<td>BMI before pregnancy (kg/m<sup>2</sup>)</td>
<td>22.9 &#x00B1; 2.7</td>
<td>23.5 &#x00B1; 3.4</td>
<td>0.137</td>
</tr>
<tr valign="top">
<td>Proteinuria (mg/24h)</td>
<td>65.8 &#x00B1; 42.1</td>
<td>296.8 &#x00B1; 114.6</td>
<td>&#x003C;0.001</td>
</tr>
<tr valign="top">
<td>SBP (mmHg)</td>
<td>113.7 &#x00B1; 10.9</td>
<td>146.4 &#x00B1; 13.1</td>
<td>&#x003C;0.001</td>
</tr>
<tr valign="top">
<td>DBP (mmHg)</td>
<td>78.6 &#x00B1; 8.2</td>
<td>103.1 &#x00B1; 9.8</td>
<td>&#x003C;0.001</td>
</tr>
<tr valign="top">
<td><italic>Parity (n, %)</italic></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr valign="top">
<td>Nulliparous</td>
<td>68 (68)</td>
<td>97 (60.6)</td>
<td>0.237</td>
</tr>
<tr valign="top">
<td>Multiparous</td>
<td>32 (32)</td>
<td>63 (39.4)</td>
<td></td>
</tr>
<tr valign="top">
<td><italic>Education status (n, %)</italic></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr valign="top">
<td>Junior high school and below</td>
<td>12 (12)</td>
<td>24 (15)</td>
<td>0.709</td>
</tr>
<tr valign="top">
<td>Senior high school or polytechnic school</td>
<td>41 (41)</td>
<td>59 (36.9)</td>
<td></td>
</tr>
<tr valign="top">
<td>College and above</td>
<td>47 (47)</td>
<td>77 (48.1)</td>
<td></td>
</tr>
<tr valign="top">
<td><italic>Clinical classification (n, %)</italic></td>
<td></td>
<td></td>
<td></td>
</tr>
<tr valign="top">
<td>GH</td>
<td>&#x2013;</td>
<td>72 (45)</td>
<td><bold>&#x2013;</bold></td>
</tr>
<tr valign="top">
<td>mPE</td>
<td></td>
<td>51 (31.9)</td>
<td></td>
</tr>
<tr valign="top">
<td>sPE</td>
<td></td>
<td>37 (23.1)</td>
<td></td>
</tr>
</tbody></table> <table-wrap-foot>
<p>The data presented are mean &#x00B1; standard deviation or <italic>n</italic> (percentage). The comparisons of data between the two groups were done by Mann&#x2013;Whitney test or Fisher&#x2019;s exact test or chi-square test. HDCP: Hypertensive disorders complicating pregnancy; BMI: Body mass index; SBP: Systolic blood pressure; DBP: Diastolic blood pressure; GH: Gestational hypertension; mPE: Mild preeclampsia; sPE: Severe preeclampsia.</p></table-wrap-foot></table-wrap> </sec>
<sec id="sec2c1"><title>Statistical analysis</title>
<p>In this study, VI, FI and VFI values were obtained from each sample measurement, and the average value of the three indexes from three measurements was used for the final statistical analysis. 3D power Doppler ultrasonography images were collected and analyzed by experienced physicians who were blinded to the experimental grouping. To validate the present intra- and inter-observer reproducibility and reliability, we asked two additional observers to perform a reanalysis of the VI data for the HDCP group. The two observers were designated A and B and each repeated the analysis twice, designated 1 and 2. The Bland&#x2013;Altman plot showed good measurement consistency between the two observers and good interobserver repeatability. Moreover, the correlation coefficients between A1 and A2 were 0.995 (0.993&#x2013;0.996) and the correlation coefficients between A and B were 0.996 (0.995&#x2013;0.997) (<xref ref-type="fig" rid="fS2">Figure S2</xref>). The data analysis was conducted with SPSS version 23 for Windows (SPSS Inc., Chicago, IL, USA). The data presented are mean &#x00B1; SD or n (percentage). The comparisons of data were performed by Fisher's exact test, unpaired <italic>t</italic>-test with Welch's correction, or one-way ANOVA followed by Dunn's multiple comparisons test. The predictive values of the parameters were determined by ROC curves. Cut-off value was calculated based on the Youden index. Logit (Combination) &#x2550; &#x2212;0.155 &#x002A; VI &#x2212;0.043 &#x002A; FI &#x2212;0.156 &#x002A; VFI. <italic>p</italic> value &#x003C; 0.05 was considered significant.</p>
</sec></sec>
<sec id="sec3"><title>Results</title>
<p>The characteristics of the pregnant women are shown in <xref ref-type="table" rid="TB1">Table 1</xref>, which reveals no significant difference between the control group and the HDCP group in maternal age, weeks of gestation at admission, pre-pregnancy body mass index (BMI), parity, and educational status. However, proteinuria, SBP, and DBP were significantly higher in the HDCP group. Of the 160 patients with HDCP, 72 had gestational hypertension (GH group), 51 had mild PE (mPE group), and 37 had severe PE (sPE group).</p>
<p>The pregnancy outcomes of the pregnant women are shown in <xref ref-type="table" rid="TB2">Table 2</xref>. The cases of prematurity, puerperal infection, postpartum hemorrhage, nonreassuring fetal status, neonatal asphyxia, placental abruption, and fetal growth restriction were significantly higher in the HDCP group. However, there was no significant difference in premature rupture of membranes between the two groups.</p>
<table-wrap id="TB2">
<label>Table 2</label>
<caption>
<p>Comparisons of pregnant outcomes between pregnant women with HDCP and without HDCP (control)</p></caption>
<table frame="hsides" rules="groups">
<colgroup>
<col span="1" align="left"/>
<col span="2" align="center"/>
<col span="3" align="center"/>
<col span="4" align="left"/>
</colgroup>
<thead>
<tr valign="bottom">
<th></th>
<th align="center" colspan="2"><bold>Study group</bold></th>
<th></th>
</tr>
<tr valign="top">
<td><bold>Characteristics</bold></td>
<td><bold>Control (<italic>n</italic> &#x2550; 100) <italic>n</italic> (%)</bold></td>
<td><bold>HDCP (<italic>n</italic> &#x2550; 160) <italic>n</italic> (%)</bold></td>
<td><bold><italic>p</italic> value</bold></td>
</tr>
</thead>
<tbody>
<tr valign="top">
<td>Prematurity</td>
<td>9 (9)</td>
<td>35 (21.9)</td>
<td>0.007</td>
</tr>
<tr valign="top">
<td>Puerperal infection</td>
<td>3 (3)</td>
<td>18 (11.3)</td>
<td>0.019</td>
</tr>
<tr valign="top">
<td>Postpartum hemorrhage</td>
<td>4 (4)</td>
<td>21 (13.1)</td>
<td>0.017</td>
</tr>
<tr valign="top">
<td>Nonreassuring fetal status</td>
<td>2 (2)</td>
<td>19 (11.9)</td>
<td>0.004</td>
</tr>
<tr valign="top">
<td>Neonatal asphyxia</td>
<td>1 (1)</td>
<td>13 (8.1)</td>
<td>0.012</td>
</tr>
<tr valign="top">
<td>Premature rupture of membranes</td>
<td>3 (3)</td>
<td>9 (5.6)</td>
<td>0.381</td>
</tr>
<tr valign="top">
<td>Placental abruption</td>
<td>0 (0)</td>
<td>7 (4.4)</td>
<td>0.046</td>
</tr>
<tr valign="top">
<td>Fetal growth restriction</td>
<td>3 (3)</td>
<td>16 (10)</td>
<td>0.048</td>
</tr>
<tr valign="top">
<td>Total poor outcomes</td>
<td>13 (13)</td>
<td>72 (45)</td>
<td>&#x003C;0.001</td>
</tr>
</tbody></table> <table-wrap-foot>
<p>The comparison of data between the two groups was done by Fisher&#x2019;s exact test. HDCP: Hypertensive disorders complicating pregnancy.</p></table-wrap-foot></table-wrap>
<p>In patients in the HDCP group, VI, FI, and VFI were significantly lower than those without HDCP (<xref ref-type="fig" rid="f1">Figure 1A&#x2013;1C</xref>). These three parameters were significantly lower in the mPE group than in the GH group, and they were significantly lower in the sPE group than in the mPE group (<xref ref-type="fig" rid="f1">Figure 1D</xref>&#x2013;<xref ref-type="fig" rid="f1">1F</xref>).</p>
<fig id="f1"><label>Figure 1.</label>
<caption>
<p><bold>Comparisons of placental three-dimensional power Doppler ultrasonography parameters in the third trimester, including VI (A), FI (B), and VFI (C) between normotensive (control, <italic>n</italic> &#x2550; 100) and HDCP (<italic>n</italic> &#x2550; 160).</bold> ***<italic>p</italic> &#x003C; 0.001, Unpaired <italic>t</italic>-test with Welch&#x2019;s correction. *<italic>p</italic> &#x003C; 0.05, **<italic>p</italic> &#x003C; 0.01, One-way ANOVA followed by a Dunn&#x2019;s multiple comparisons test. Comparisons of placental three-dimensional power Doppler ultrasonography parameters in the third trimester VI (A), FI (B), and VFI (C) among GH (<italic>n</italic> &#x2550; 72), mPE (<italic>n</italic> &#x2550; 51), and sPE (<italic>n</italic> &#x2550; 37). VI: Vascularization index; FI: Flow index; VFI: Vascularization flow index; HDCP: Hypertensive disorders complicating pregnancy; GH: Gestational hypertension; mPE: Mild preeclampsia; sPE: Severe preeclampsia.</p>
</caption>
<graphic xlink:href="bb-2023-9085f1.jpeg"/></fig>
<p>Of the 160 patients with HDCP, 72 had a poor outcome. In the HDCP patients with good outcomes, VI, FI, and VFI were all significantly higher than in those patients with poor outcomes (<xref ref-type="fig" rid="f2">Figure 2A&#x2013;2C</xref>).</p>
<fig id="f2"><label>Figure 2.</label>
<caption>
<p><bold>Comparisons of placental three-dimensional power Doppler ultrasonography parameters in the third trimester, including VI (A), FI (B), and VFI (C) between good pregnant outcomes (<italic>n</italic> &#x2550; 88) and poor pregnant outcomes (<italic>n</italic> &#x2550; 72) among pregnant women with hypertensive disorders complicating pregnancy.</bold> **<italic>p</italic> &#x003C; 0.01, ***<italic>p</italic> &#x003C; 0.001, Unpaired <italic>t</italic>-test with Welch&#x2019;s correction. VI: Vascularization index; FI: Flow index; VFI: Vascularization flow index.</p>
</caption>
<graphic xlink:href="bb-2023-9085f2.jpeg"/></fig>
<table-wrap id="TB3">
<label>Table 3</label>
<caption>
<p>Predictive values in ROC analysis.</p></caption>
<table frame="hsides" rules="groups">
<colgroup>
<col span="1" align="left"/>
<col span="2" align="left"/>
<col span="3" align="left"/>
<col span="4" align="left"/>
<col span="5" align="left"/>
<col span="6" align="left"/>
<col span="7" align="left"/>
</colgroup>
<thead>
<tr valign="bottom">
<th align="left"/>
<th><bold>Cut-off value</bold></th>
<th><bold>AUC (95% CI)</bold></th>
<th><bold><italic>p</italic> value</bold></th>
<th><bold>Sensitivity (%)</bold></th>
<th><bold>Specificity (%)</bold></th>
<th><bold>Youden index</bold></th>
</tr>
</thead>
<tbody>
<tr valign="top">
<td>VI</td>
<td>14.3</td>
<td>0.69 (0.60&#x2013;0.77)</td>
<td>&#x003C;0.001</td>
<td>54.17</td>
<td>84.09</td>
<td>0.38</td>
</tr>
<tr valign="top">
<td>FI</td>
<td>37.66</td>
<td>0.63 (0.54&#x2013;0.71)</td>
<td>0.006</td>
<td>79.17</td>
<td>48.86</td>
<td>0.28</td>
</tr>
<tr valign="top">
<td>VFI</td>
<td>7.71</td>
<td>0.66 (0.57&#x2013;0.75)</td>
<td>&#x003C;0.001</td>
<td>72.22</td>
<td>67.05</td>
<td>0.39</td>
</tr>
<tr valign="top">
<td>Combination<sup>&#x002A;</sup></td>
<td>&#x2013;</td>
<td>0.75 (0.68&#x2013;0.83)</td>
<td>&#x003C;0.001</td>
<td>77.78</td>
<td>70.45</td>
<td>0.48</td>
</tr>
</tbody></table> <table-wrap-foot>
<p><sup>&#x002A;</sup>Logit (Combination) &#x2550; &#x2212;0.155 &#x002A; VI-0.043 &#x002A; FI-0.156 &#x002A; VFI. ROC: Receiver operating characteristic; AUC: Area under the curve; CI: Confidence interval; VI: Vascularization index; FI: Flow index; VFI: Vascularization flow index.</p></table-wrap-foot></table-wrap>
<p>The area under the curve (AUC) of VI in predicting pregnancy outcome in pregnant women with HDCP was 0.69 (95% CI 0.60&#x2013;0.77), with a sensitivity of 54.17% and a specificity of 84.09% (<xref ref-type="fig" rid="f3">Figure 3</xref> and <xref ref-type="table" rid="TB3">Table 3</xref>). The AUC of FI for predicting pregnancy outcome in pregnant women with HDCP was 0.63 (95% CI 0.54&#x2013;0.71), with a sensitivity of 79.17% and a specificity of 48.86% (<xref ref-type="fig" rid="f3">Figure 3B</xref> and <xref ref-type="table" rid="TB3">Table 3</xref>). The AUC of VFI for predicting pregnancy outcome in pregnant women with HDCP was 0.66 (95% CI 0.57&#x2013;0.75), with a sensitivity of 72.22% and a specificity of 67.05% (<xref ref-type="fig" rid="f3">Figure 3B</xref> and <xref ref-type="table" rid="TB3">Table 3</xref>). The AUC of the combination of these three parameters for predicting pregnancy outcome in pregnant women with HDCP was 0.75 (95% CI 0.68&#x2013;0.83), with a sensitivity of 77.78% and a specificity of 70.45% (<xref ref-type="fig" rid="f3">Figure 3C</xref> and <xref ref-type="table" rid="TB3">Table 3</xref>).</p>
<fig id="f3"><label>Figure 3.</label>
<caption>
<p><bold>ROC analysis of predictive values of placental three-dimensional power Doppler ultrasonography parameters in the third trimester for pregnant outcomes among pregnant women with hypertensive disorders complicating pregnancy.</bold> VFI: Vascularization flow index; FI: Flow index; VI: Vascularization index; ROC: Receiver operating characteristic.</p>
</caption>
<graphic xlink:href="bb-2023-9085f3.jpeg"/></fig></sec>
<sec id="sec4"><title>Discussion</title>
<p>Hypertension in pregnancy is a unique obstetric complication that affects pregnant women. Its main features include widespread vasoconstriction and impaired uteroplacental perfusion, which can lead to serious maternal and fetal complications and affect the lives of mothers and children [<xref rid="ref14" ref-type="bibr">14</xref>]. According to studies, the worldwide incidence of hypertension during pregnancy is approximately 10%, and 13% of maternal deaths attributable to direct obstetric factors are related to PE [<xref rid="ref1" ref-type="bibr">1</xref>]. The main clinical manifestations of hypertension in pregnancy are elevated blood pressure with or without proteinuria and edema. If the disease progresses rapidly, convulsions and coma may occur [<xref rid="ref15" ref-type="bibr">15</xref>]. Currently, the etiology and pathogenesis of hypertension in pregnancy are thought to be a combination of fetal, placental, and maternal factors [<xref rid="ref16" ref-type="bibr">16</xref>]. Early determination and prediction of the severity of hypertension in pregnancy may help to reduce the complication rate and mortality of maternal and perinatal diseases and is therefore of great value.</p>
<p>Since the application of 3D power Doppler ultrasonography, its increasing color sensitivity, and combined use with computerized software have enabled quantitative analysis of placental blood perfusion [<xref rid="ref17" ref-type="bibr">17</xref>, <xref rid="ref18" ref-type="bibr">18</xref>]. Placental vascular sonobiopsy using 3D power Doppler ultrasound is used to assess placental vascularization in normal and growth-restricted fetuses [<xref rid="ref19 ref20 ref21" ref-type="bibr">19&#x2013;21</xref>]. 3D power Doppler ultrasound also shows that the vascularity and flow intensity of the placenta in normal pregnancy are different from those in PE [<xref rid="ref22" ref-type="bibr">22</xref>, <xref rid="ref23" ref-type="bibr">23</xref>].</p>
<p>The aim of this study was to compare the changes in 3D power Doppler ultrasonography parameters VI, FI, and VFI between HDCP patients and non-HDCP pregnant women in late pregnancy and to evaluate the predictive value of these parameters for pregnancy outcome in HDCP patients. These results may provide a valid clinical assessment index to reduce perinatal mortality.</p>
<p>Several studies have confirmed that the pathological basis of HDCP is systemic spasm of small arteries, which impairs microvascular circulation and increases capillary permeability [<xref rid="ref24" ref-type="bibr">24</xref>]. Maternal hypertensive disease may lead to an increase in blood volume and pressure in the placental circulation, resulting in acute necrotizing arteritis and vascular embolism, reducing the effective exchange area and causing ischemia and hypoxia in the placental tissue. In severe cases, local tissue hemorrhage, necrosis, infarction, and circulatory disorders between the fetus and the placenta may also occur [<xref rid="ref25" ref-type="bibr">25</xref>].</p>
<p>Placenta is a special and important organ between mother and fetus, and its function directly affects the health of the fetus. However, intra-placental blood flow velocity is low, and color Doppler ultrasonography cannot effectively monitor the intra-placental vascular tree because of the direction of blood flow [<xref rid="ref26" ref-type="bibr">26</xref>]. In contrast, 3D power Doppler ultrasonography can visualize low-velocity blood flow and is independent of the direction of blood flow, which clearly reveals the tertiary structure of intra-placental villi vessels [<xref rid="ref27" ref-type="bibr">27</xref>]. VI, FI, and VFI are new indicators of placental blood flow assessed by 3D power Doppler ultrasonography [<xref rid="ref11" ref-type="bibr">11</xref>]. All three indices are significantly affected by volume flow, attenuation, vessel number, and erythrocyte density [<xref rid="ref28" ref-type="bibr">28</xref>]. In normal pregnancies, all placental vascular indices estimated by 3D power Doppler ultrasonography had a constant distribution throughout pregnancy [<xref rid="ref29" ref-type="bibr">29</xref>]. VI represents the number of vessels detected per unit volume and is used to indicate the sparseness of vessel distribution. FI is the number of blood cells passed during the 3D energy scan and VFI is the combination of VI and FI. Studies have shown that as the gestational week increases, blood vessels in the placenta enlarge and thicken, blood flow increases, and VI, FI, and VFI also increase [<xref rid="ref30" ref-type="bibr">30</xref>]. It has been reported that placental vascular indices in 3D power Doppler measurements are influenced by the location of placental implantation [<xref rid="ref18" ref-type="bibr">18</xref>]. The position of the placental attachment in the uterine cavity leads to a significant decrease in the individual indices as the distance between the transducer and the vessel increases [<xref rid="ref28" ref-type="bibr">28</xref>]. Some studies have shown that only the anterior placentas should be included in studies to avoid the risk of Doppler signal attenuation [<xref rid="ref19" ref-type="bibr">19</xref>, <xref rid="ref31" ref-type="bibr">31</xref>]. Therefore, patients with inadequate placental localization, including anterior and posterior placentas, were excluded in this study.</p>
<p>After comparing the 3D power Doppler ultrasonography parameters of the placenta VI, FI, and VFI in late pregnancy between control and HDCP patients, we found that all three parameters were significantly decreased in patients with HDCP. We then compared the differences in these three parameters between patients with different severity of HDCP and observed a decreasing trend in VI, FI, and VFI with increasing severity of HDCP.</p>
<p>Based on <xref ref-type="table" rid="TB2">Table 2</xref>, we analyzed prematurity, puerperal infection, postpartum hemorrhage, nonreassuring fetal status, neonatal asphyxia, placental abruption, fetal growth restriction, and premature rupture of membranes in patients with HDCP and confirmed that 72 patients (45%) had adverse pregnancy outcomes. When comparing the 3D power Doppler ultrasonography parameters of late pregnancy VI, FI, and VFI between the poor-outcome and good-outcome groups, it was found that all three parameters were significantly reduced in the poor-outcome group.</p>
<p>In this study, we analyzed the predictive value of 3D power Doppler ultrasonography parameters for pregnancy outcome in HDCP patients using ROC and determined the cut-off value based on the maximum value of the Youden index. The results showed that the 3D power Doppler ultrasonography parameters VI, FI, and VFI of the placenta in late pregnancy were effective in predicting pregnancy outcome in patients with HDCP, and the combination of the three parameters significantly improved the Youden index.</p>
<p>However, this study had some limitations. Although the total population of the study was relatively large, the small sample size of patients with gestational hypertension, mild PE, and severe PE may have reduced the power of this study. In addition, this study did not collect long-term outcome data for the offspring. In addition, differences in placental flow were not compared with individual abnormal outcomes, and sensitivity, specificity, and AUC analysis did not show ideal accuracy, which needs to be further verified in future larger-scale studies. Because our study population included only women from a single tertiary center, our data may not be representative of the entire population.</p>
</sec>
<sec id="sec5"><title>Conclusion</title>
<p>Placental hemodynamics are altered in patients with HDCP, which seriously affects maternal and fetal health. This study suggests that 3D power Doppler ultrasonography parameters can reflect the perfusion status of the placenta and predict pregnancy outcome in patients with HDCP. By monitoring the relevant hemodynamic parameters, valuable information can be obtained for clinical diagnosis, objective evaluation, and treatment of HDCP.</p>
</sec>
<sec sec-type="supplementary-material" id="sec6"><title>Supplemental Data</title>
<p></p>
<fig id="fS1"><label>Figure S1.</label>
<caption>
<p><bold>Representative spherical contour of the placenta measured by three-dimensional power Doppler ultrasonography and the output of the vocal analysis.</bold> CFM: Color flow mode.</p>
</caption>
<graphic xlink:href="bb-2023-9085f4.jpeg"/></fig>
<fig id="fS2"><label>Figure S2.</label>
<caption>
<p><bold>Bland&#x2013;Altman plots of present intra- and inter-observer reproducibility and reliability of vascularization index in hypertensive disorders complicating pregnancy</bold> <bold>group</bold>. A and B: Two observers; 1, 2: Double analysis for each observer; SD: Standard deviation.</p>
</caption>
<graphic xlink:href="bb-2023-9085f5.jpeg"/></fig></sec></body>
<back>
<ref-list>
<title>References</title>
<ref id="ref1">
<label>1</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sutton</surname>
<given-names>ALM</given-names>
</name>
<name>
<surname>Harper</surname>
<given-names>LM</given-names>
</name>
<name>
<surname>Tita</surname>
<given-names>ATN</given-names>
</name>
</person-group> 
<article-title>Hypertensive disorders in pregnancy</article-title>
<source>Obstet Gynecol Clin North Am</source> <year>2018</year>
<volume>45</volume>
<issue>2</issue>
<fpage>333</fpage>
<lpage>47</lpage>
<comment>https://doi.org/10.1016/j.ogc.2018.01.012</comment>
</element-citation>
</ref>
<ref id="ref2">
<label>2</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Li</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Qin</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Chen</surname>
<given-names>L</given-names>
</name>
</person-group> 
<article-title>Prevalence of hypertensive disorders in pregnancy in China: a systematic review and meta-analysis</article-title>
<source>Pregnancy Hypertens</source> <year>2021</year>
<volume>24</volume>
<fpage>13</fpage>
<lpage>21</lpage>
<comment>https://doi.org/10.1016/j.preghy.2021.02.001</comment>
</element-citation>
</ref>
<ref id="ref3">
<label>3</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Folk</surname>
<given-names>DM</given-names>
</name>
</person-group> 
<article-title>Hypertensive disorders of pregnancy: overview and current recommendations</article-title>
<source>J Midwifery Womens Health</source> <year>2018</year>
<volume>63</volume>
<issue>3</issue>
<fpage>289</fpage>
<lpage>300</lpage>
<comment>https://doi.org/10.1111/jmwh.12725</comment>
</element-citation>
</ref>
<ref id="ref4">
<label>4</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Turner</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Hameed</surname>
<given-names>AB</given-names>
</name>
</person-group> 
<article-title>Hypertensive disorders in pregnancy current practice review</article-title>
<source>Curr Hypertens Rev</source> <year>2017</year>
<volume>13</volume>
<issue>2</issue>
<fpage>80</fpage>
<lpage>8</lpage>
<comment>https://doi.org/10.2174/1573402113666170529110024</comment>
</element-citation>
</ref>
<ref id="ref5">
<label>5</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Xiao</surname>
<given-names>Z</given-names>
</name>
<name>
<surname>Wang</surname>
<given-names>Y</given-names>
</name>
<name>
<surname>Thai</surname>
<given-names>PN</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>X</given-names>
</name>
<name>
<surname>Lu</surname>
<given-names>X</given-names>
</name>
<name>
<surname>Pu</surname>
<given-names>J</given-names>
</name>
</person-group> 
<article-title>Mechanisms linking hyperglycemia in pregnancy to the offspring cardiovascular system dysfunction</article-title>
<source>STEMedicine</source> <year>2021</year>
<volume>2</volume>
<issue>7</issue>
<fpage>e91</fpage>
<comment>https://doi.org/10.37175/stemedicine.v2i7.91</comment>
</element-citation>
</ref>
<ref id="ref6">
<label>6</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Vasapollo</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Lo Presti</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Gagliardi</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Farsetti</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Tiralongo</surname>
<given-names>GM</given-names>
</name>
<name>
<surname>Pisani</surname>
<given-names>I</given-names>
</name> <etal/>
</person-group> 
<article-title>Restricted physical activity in pregnancy reduces maternal vascular resistance and improves fetal growth</article-title>
<source>Ultrasound Obstet Gynecol</source> <year>2018</year>
<volume>51</volume>
<issue>5</issue>
<fpage>672</fpage>
<lpage>6</lpage>
<comment>https://doi.org/10.1002/uog.17489</comment>
</element-citation>
</ref>
<ref id="ref7">
<label>7</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hauspurg</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Countouris</surname>
<given-names>ME</given-names>
</name>
<name>
<surname>Catov</surname>
<given-names>JM</given-names>
</name>
</person-group> 
<article-title>Hypertensive disorders of pregnancy and future maternal health: how can the evidence guide postpartum management?</article-title>
<source>Curr Hypertens Rep</source> <year>2019</year>
<volume>21</volume>
<issue>12</issue>
<fpage>96</fpage>
<comment>https://doi.org/10.1007/s11906-019-0999-7</comment>
</element-citation>
</ref>
<ref id="ref8">
<label>8</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Leavitt</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Obican</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Yankowitz</surname>
<given-names>J</given-names>
</name>
</person-group> 
<article-title>Treatment and prevention of hypertensive disorders during pregnancy</article-title>
<source>Clin Perinatol</source> <year>2019</year>
<volume>46</volume>
<issue>2</issue>
<fpage>173</fpage>
<lpage>85</lpage>
<comment>https://doi.org/10.1016/j.clp.2019.02.002</comment>
</element-citation>
</ref>
<ref id="ref9">
<label>9</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhou</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Xiong</surname>
<given-names>Y</given-names>
</name>
<name>
<surname>Ren</surname>
<given-names>Y</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>Y</given-names>
</name>
<name>
<surname>Li</surname>
<given-names>X</given-names>
</name>
<name>
<surname>Yan</surname>
<given-names>Y</given-names>
</name>
</person-group> 
<article-title>Three-dimensional power Doppler ultrasonography indicates that increased placental blood perfusion during the third trimester is associated with the risk of macrosomia at birth</article-title>
<source>J Clin Ultrasound</source> <year>2021</year>
<volume>49</volume>
<issue>1</issue>
<fpage>12</fpage>
<lpage>9</lpage>
<comment>https://doi.org/10.1002/jcu.22912</comment>
</element-citation>
</ref>
<ref id="ref10">
<label>10</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Schiffer</surname>
<given-names>V</given-names>
</name>
<name>
<surname>Pellaers</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Hoenen</surname>
<given-names>J</given-names>
</name>
<name>
<surname>van Kuijk</surname>
<given-names>SMJ</given-names>
</name>
<name>
<surname>Spaanderman</surname>
<given-names>MEA</given-names>
</name>
<name>
<surname>Al-Nasiry</surname>
<given-names>S</given-names>
</name>
</person-group> 
<article-title>Feasibility of three dimensional power Doppler ultrasonography methods to assess placental perfusion</article-title>
<source>Eur J Obstet Gynecol Reprod Biol</source> <year>2020</year>
<volume>254</volume>
<fpage>321</fpage>
<lpage>8</lpage>
<comment>https://doi.org/10.1016/j.ejogrb.2020.08.006</comment>
</element-citation>
</ref>
<ref id="ref11">
<label>11</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Yamasato</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Zalud</surname>
<given-names>I</given-names>
</name>
</person-group> 
<article-title>Three dimensional power Doppler of the placenta and its clinical applications</article-title>
<source>J Perinat Med</source> <year>2017</year>
<volume>45</volume>
<issue>6</issue>
<fpage>693</fpage>
<lpage>700</lpage>
<comment>https://doi.org/10.1515/jpm-2016-0366</comment>
</element-citation>
</ref>
<ref id="ref12">
<label>12</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Abdallah</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Khairy</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Tawfik</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Mohamed</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Abdel-Rasheed</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Salem</surname>
<given-names>S</given-names>
</name> <etal/>
</person-group> 
<article-title>Role of first-trimester three-dimensional (3D) power Doppler of placental blood flow and 3D placental volume in early prediction of pre-eclampsia</article-title>
<source>Int J Gynaecol Obstet</source> <year>2021</year>
<volume>154</volume>
<issue>3</issue>
<fpage>466</fpage>
<lpage>73</lpage>
<comment>https://doi.org/10.1002/ijgo.13572</comment>
</element-citation>
</ref>
<ref id="ref13">
<label>13</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pinter</surname>
<given-names>SZ</given-names>
</name>
<name>
<surname>Kripfgans</surname>
<given-names>OD</given-names>
</name>
<name>
<surname>Treadwell</surname>
<given-names>MC</given-names>
</name>
<name>
<surname>Kneitel</surname>
<given-names>AW</given-names>
</name>
<name>
<surname>Fowlkes</surname>
<given-names>JB</given-names>
</name>
<name>
<surname>Rubin</surname>
<given-names>JM</given-names>
</name>
</person-group> 
<article-title>Evaluation of umbilical vein blood volume flow in preeclampsia by angle-independent 3D sonography</article-title>
<source>J Ultrasound Med</source> <year>2018</year>
<volume>37</volume>
<issue>7</issue>
<fpage>1633</fpage>
<lpage>40</lpage>
<comment>https://doi.org/10.1002/jum.14507</comment>
</element-citation>
</ref>
<ref id="ref14">
<label>14</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Huckstep</surname>
<given-names>O</given-names>
</name>
<name>
<surname>Lewandowski</surname>
<given-names>AJ</given-names>
</name>
<name>
<surname>Leeson</surname>
<given-names>P</given-names>
</name>
</person-group> 
<article-title>Invited commentary: hypertension during pregnancy and offspring microvascular structure-insights from the retinal microcirculation</article-title>
<source>Am J Epidemiol</source> <year>2016</year>
<volume>184</volume>
<issue>9</issue>
<fpage>616</fpage>
<lpage>8</lpage>
<comment>https://doi.org/10.1093/aje/kww060</comment>
</element-citation>
</ref>
<ref id="ref15">
<label>15</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Magee</surname>
<given-names>LA</given-names>
</name>
<name>
<surname>von Dadelszen</surname>
<given-names>P</given-names>
</name>
</person-group> 
<article-title>State-of-the-art diagnosis and treatment of hypertension in pregnancy</article-title>
<source>Mayo Clin Proc</source> <year>2018</year>
<volume>93</volume>
<issue>11</issue>
<fpage>1664</fpage>
<lpage>77</lpage>
<comment>https://doi.org/10.1016/j.mayocp.2018.04.033</comment>
</element-citation>
</ref>
<ref id="ref16">
<label>16</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ankumah</surname>
<given-names>NE</given-names>
</name>
<name>
<surname>Sibai</surname>
<given-names>BM</given-names>
</name>
</person-group> 
<article-title>Chronic hypertension in pregnancy: diagnosis, management, and outcomes</article-title>
<source>Clin Obstet Gynecol</source> <year>2017</year>
<volume>60</volume>
<issue>1</issue>
<fpage>206</fpage>
<lpage>14</lpage>
<comment>https://doi.org/10.1097/GRF.0000000000000255</comment>
</element-citation>
</ref>
<ref id="ref17">
<label>17</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Cali</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Foti</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Minneci</surname>
<given-names>G</given-names>
</name>
</person-group> 
<article-title>3D power Doppler in the evaluation of abnormally invasive placenta</article-title>
<source>J Perinat Med</source> <year>2017</year>
<volume>45</volume>
<issue>6</issue>
<fpage>701</fpage>
<lpage>9</lpage>
<comment>https://doi.org/10.1515/jpm-2016-0387</comment>
</element-citation>
</ref>
<ref id="ref18">
<label>18</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hata</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Tanaka</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Noguchi</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Hata</surname>
<given-names>K</given-names>
</name>
</person-group> 
<article-title>Three-dimensional ultrasound evaluation of the placenta</article-title>
<source>Placenta</source> <year>2011</year>
<volume>32</volume>
<issue>2</issue>
<fpage>105</fpage>
<lpage>15</lpage>
<comment>https://doi.org/10.1016/j.placenta.2010.11.001</comment>
</element-citation>
</ref>
<ref id="ref19">
<label>19</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Noguchi</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Hata</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Tanaka</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Hata</surname>
<given-names>T</given-names>
</name>
</person-group> 
<article-title>Placental vascular sonobiopsy using three-dimensional power Doppler ultrasound in normal and growth restricted fetuses</article-title>
<source>Placenta</source> <year>2009</year>
<volume>30</volume>
<issue>5</issue>
<fpage>391</fpage>
<lpage>7</lpage>
<comment>https://doi.org/10.1016/j.placenta.2009.02.010</comment>
</element-citation>
</ref>
<ref id="ref20">
<label>20</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Noguchi</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Tanaka</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Koyanagi</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Miyake</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Hata</surname>
<given-names>T</given-names>
</name>
</person-group> 
<article-title>Three-dimensional power Doppler indices at 18-22 weeks&#x2019; gestation for prediction of fetal growth restriction or pregnancy-induced hypertension</article-title>
<source>Arch Gynecol Obstet</source> <year>2015</year>
<volume>292</volume>
<issue>1</issue>
<fpage>75</fpage>
<lpage>9</lpage>
<comment>https://doi.org/10.1007/s00404-014-3603-z</comment>
</element-citation>
</ref>
<ref id="ref21">
<label>21</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bozkurt</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Basgul Yigiter</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Gokaslan</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Kavak</surname>
<given-names>ZN</given-names>
</name>
</person-group> 
<article-title>Correlations of fetal-maternal outcomes and first trimester 3-D placental volume/3-D power Doppler calculations</article-title>
<source>Clin Exp Obstet Gynecol</source> <year>2010</year>
<volume>37</volume>
<issue>1</issue>
<fpage>26</fpage>
<lpage>8</lpage>
</element-citation>
</ref>
<ref id="ref22">
<label>22</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Costa</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Rice</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Cardwell</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Hunter</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Ong</surname>
<given-names>S</given-names>
</name>
</person-group> 
<article-title>An assessment of vascularity and flow intensity of the placenta in normal pregnancy and pre-eclampsia using three-dimensional ultrasound</article-title>
<source>J Matern Fetal Neonatal Med</source> <year>2010</year>
<volume>23</volume>
<issue>8</issue>
<fpage>894</fpage>
<lpage>9</lpage>
<comment>https://doi.org/10.3109/14767051003649862</comment>
</element-citation>
</ref>
<ref id="ref23">
<label>23</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Odeh</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Ophir</surname>
<given-names>E</given-names>
</name>
<name>
<surname>Maximovsky</surname>
<given-names>O</given-names>
</name>
<name>
<surname>Grinin</surname>
<given-names>V</given-names>
</name>
<name>
<surname>Bornstein</surname>
<given-names>J</given-names>
</name>
</person-group> 
<article-title>Placental volume and three-dimensional power Doppler analysis in prediction of pre-eclampsia and small for gestational age between week 11 and 13 weeks and 6 days of gestation</article-title>
<source>Prenat Diagn</source> <year>2011</year>
<volume>31</volume>
<issue>4</issue>
<fpage>367</fpage>
<lpage>71</lpage>
<comment>https://doi.org/10.1002/pd.2697</comment>
</element-citation>
</ref>
<ref id="ref24">
<label>24</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Stepan</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Hund</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Andraczek</surname>
<given-names>T</given-names>
</name>
</person-group> 
<article-title>Combining biomarkers to predict pregnancy complications and redefine preeclampsia: the angiogenic-placental syndrome</article-title>
<source>Hypertension</source> <year>2020</year>
<volume>75</volume>
<issue>4</issue>
<fpage>918</fpage>
<lpage>26</lpage>
<comment>https://doi.org/10.1161/HYPERTENSIONAHA.119.13763</comment>
</element-citation>
</ref>
<ref id="ref25">
<label>25</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lo</surname>
<given-names>JO</given-names>
</name>
<name>
<surname>Mission</surname>
<given-names>JF</given-names>
</name>
<name>
<surname>Caughey</surname>
<given-names>AB</given-names>
</name>
</person-group> 
<article-title>Hypertensive disease of pregnancy and maternal mortality</article-title>
<source>Curr Opin Obstet Gynecol</source> <year>2013</year>
<volume>25</volume>
<issue>2</issue>
<fpage>124</fpage>
<lpage>32</lpage>
<comment>https://doi.org/10.1097/GCO.0b013e32835e0ef5</comment>
</element-citation>
</ref>
<ref id="ref26">
<label>26</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rezk</surname>
<given-names>MA</given-names>
</name>
<name>
<surname>Shawky</surname>
<given-names>M</given-names>
</name>
</person-group> 
<article-title>Grey-scale and colour Doppler ultrasound versus magnetic resonance imaging for the prenatal diagnosis of placenta accreta</article-title>
<source>J Matern Fetal Neonatal Med</source> <year>2016</year>
<volume>29</volume>
<issue>2</issue>
<fpage>218</fpage>
<lpage>23</lpage>
<comment>https://doi.org/10.3109/14767058.2014.993604</comment>
</element-citation>
</ref>
<ref id="ref27">
<label>27</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Gould</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Cawyer</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Dell&#x2019;Italia</surname>
<given-names>L</given-names>
</name>
<name>
<surname>Harper</surname>
<given-names>L</given-names>
</name>
<name>
<surname>McGwin</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Bamman</surname>
<given-names>M</given-names>
</name>
</person-group> 
<article-title>Resistance training does not decrease placental blood flow during valsalva maneuver: a novel use of 3D Doppler power flow ultrasonography</article-title>
<source>Sports Health</source> <year>2021</year>
<volume>13</volume>
<issue>5</issue>
<fpage>476</fpage>
<lpage>81</lpage>
<comment>https://doi.org/10.1177/19417381211000717</comment>
</element-citation>
</ref>
<ref id="ref28">
<label>28</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Raine-Fenning</surname>
<given-names>NJ</given-names>
</name>
<name>
<surname>Nordin</surname>
<given-names>NM</given-names>
</name>
<name>
<surname>Ramnarine</surname>
<given-names>KV</given-names>
</name>
<name>
<surname>Campbell</surname>
<given-names>BK</given-names>
</name>
<name>
<surname>Clewes</surname>
<given-names>JS</given-names>
</name>
<name>
<surname>Perkins</surname>
<given-names>A</given-names>
</name> <etal/>
</person-group> 
<article-title>Determining the relationship between three-dimensional power Doppler data and true blood flow characteristics: an in-vitro flow phantom experiment</article-title>
<source>Ultrasound Obstet Gynecol</source> <year>2008</year>
<volume>32</volume>
<issue>4</issue>
<fpage>540</fpage>
<lpage>50</lpage>
<comment>https://doi.org/10.1002/uog.6110</comment>
</element-citation>
</ref>
<ref id="ref29">
<label>29</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>de Paula</surname>
<given-names>CF</given-names>
</name>
<name>
<surname>Ruano</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Campos</surname>
<given-names>JA</given-names>
</name>
<name>
<surname>Zugaib</surname>
<given-names>M</given-names>
</name>
</person-group> 
<article-title>Quantitative analysis of placental vasculature by three-dimensional power Doppler ultrasonography in normal pregnancies from 12 to 40 weeks of gestation</article-title>
<source>Placenta</source> <year>2009</year>
<volume>30</volume>
<issue>2</issue>
<fpage>142</fpage>
<lpage>8</lpage>
<comment>https://doi.org/10.1016/j.placenta.2008.11.010</comment>
</element-citation>
</ref>
<ref id="ref30">
<label>30</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lin</surname>
<given-names>X</given-names>
</name>
<name>
<surname>Zhou</surname>
<given-names>X</given-names>
</name>
<name>
<surname>Jin</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Zhao</surname>
<given-names>Y</given-names>
</name>
</person-group> 
<article-title>Relationship between 3D power Doppler ultrasound and serum MMP-2 and Ang-2 levels in pregnant women with preeclampsia</article-title>
<source>J Coll Physicians Surg Pak</source> <year>2020</year>
<volume>30</volume>
<issue>8</issue>
<fpage>810</fpage>
<lpage>4</lpage>
<comment>https://doi.org/10.29271/jcpsp.2020.08.810</comment>
</element-citation>
</ref>
<ref id="ref31">
<label>31</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zalud</surname>
<given-names>I</given-names>
</name>
<name>
<surname>Shaha</surname>
<given-names>S</given-names>
</name>
</person-group> 
<article-title>Three-dimensional sonography of the placental and uterine spiral vasculature: influence of maternal age and parity</article-title>
<source>J Clin Ultrasound</source> <year>2008</year>
<volume>36</volume>
<issue>7</issue>
<fpage>391</fpage>
<lpage>6</lpage>
<comment>https://doi.org/10.1002/jcu.20485</comment>
</element-citation>
</ref>
</ref-list> 
 
<fn-group>
<fn fn-type="conflict">
<p>Conflicts of interest:  Authors declare no conflicts of interest.</p>
</fn>
<fn fn-type="supported-by">
<p>Funding:  Authors received no specific funding for this work.</p>
</fn>
</fn-group></back></article>