﻿<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD Journal Publishing DTD v2.3 20070202//EN" "journalpublishing.dtd">
<article article-type="review-article" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:mml="http://www.w3.org/1998/Math/MathML">
<front>
<journal-meta>
<journal-id journal-id-type="nlm-ta">Biomol Biomed</journal-id>
<journal-title>Biomolecules and Biomedicine</journal-title>
<issn pub-type="ppub">2831-0896</issn>
<issn pub-type="epub">2831-090X</issn>
<publisher>
<publisher-name>Association of Basic Medical Sciences of Federation of Bosnia and Herzegovina</publisher-name>
</publisher>
</journal-meta>
<article-meta>
<article-id pub-id-type="publisher-id">BB-23-949</article-id>
<article-id pub-id-type="doi">10.17305/bb.2023.9154</article-id>
<article-categories>
<subj-group subj-group-type="heading">
<subject>Review</subject>
</subj-group>
</article-categories>
<title-group>
<article-title>Videolaryngoscopy as a primary intubation modality in obstetrics: A narrative review of current evidence</article-title>
</title-group>
<contrib-group>
<contrib contrib-type="author">
<name>
<surname>Pintari&#x010D;</surname>
<given-names>Tatjana Stopar</given-names>
</name>
<uri content-type="orcid">https://orcid.org/0000-0003-2750-5386</uri>
<xref rid="aff1" ref-type="aff">1</xref>
<xref rid="aff2" ref-type="aff">2</xref>
<xref rid="cor1" ref-type="corresp">&#x002A;</xref>
</contrib>
</contrib-group>
<aff id="aff1"><label>1</label>Department of Anaesthesiology and Intensive Therapy, University Medical Centre Ljubljana, Ljubljana, Slovenia</aff>
<aff id="aff2"><label>2</label>Institute of Anatomy, Medical Faculty, University of Ljubljana, Ljubljana, Slovenia</aff>
<author-notes>
<corresp id="cor1"><label>&#x002A;</label>Correspondence to Tatjana Stopar Pintari&#x010D;: <email xlink:href="mailto:tatjanas38@gmail.com">tatjanas38@gmail.com</email></corresp>
</author-notes>
<pub-date pub-type="ppub">
<day>1</day>
<month>12</month>
<year>2023</year>
</pub-date>
<pub-date pub-type="epub">
<day>1</day>
<month>12</month>
<year>2023</year>
</pub-date>
<volume>23</volume>
<issue>6</issue>
<fpage>949</fpage>
<lpage>955</lpage>
<history>
<date date-type="received">
<day>8</day>
<month>2</month>
<year>2023</year>
</date>
<date date-type="accepted">
<day>6</day>
<month>4</month>
<year>2023</year>
</date>
<date date-type="rev-recd">
<day>28</day>
<month>3</month>
<year>2023</year>
</date>
</history>
<permissions>
<copyright-statement>&#x00A9; 2023 Stopar Pintari&#x010D;.</copyright-statement>
<copyright-year>2023</copyright-year>
<license license-type="standard"><p>This article is available under a Creative Commons License (Attribution 4.0 International, as described at <ext-link ext-link-type="uri" xlink:href="https://creativecommons.org/licenses/by/4.0/">https://creativecommons.org/licenses/by/4.0/</ext-link>).</p>
</license>
</permissions>
<abstract>
<p>Pregnancy-related physiologic and anatomic changes affect oxygenation and airway management, and it is widely believed that airway difficulty may be more common in obstetric patients as a result. In addition, most obstetric intubations are performed under emergency conditions, and preoperative airway assessment poorly predicts airway management outcomes. These considerations necessitate special protocols for airway care in the obstetric population, and the evolution of the videolaryngoscope represents one of the most important milestones in recent decades. However, recommendations for the use of videolaryngoscopy in obstetrics remain unclear. A considerable body of evidence affirms that videolaryngoscopy improves laryngeal visualization, increases first-attempt and overall intubation success rates, shortens intubation time, and facilitates team communication and education. In contrast, a significant number of studies have also reported conflicting results regarding comparative clinical outcomes and have highlighted other limitations regarding the adoption of videolaryngoscopy in routine obstetric care. Nevertheless, considering the peculiarities of obstetric intubation, the Macintosh-style videolaryngoscope can be suggested as the primary intubation device as it offers the benefits of both videolaryngoscopy and direct laryngoscopy. However, more rigorous evidence is needed to clarify the current blind spots and controversies regarding the role of videolaryngoscopy in obstetrics.</p>
</abstract>
<kwd-group>
<kwd>Videolaryngoscopy</kwd>
<kwd>direct laryngoscopy</kwd>
<kwd>endotracheal intubation</kwd>
<kwd>obstetric anaesthesia</kwd>
<kwd>airway management</kwd>
</kwd-group>
</article-meta>
</front>
<body>
<sec id="sec1"><title>Introduction</title>
<p>The obstetric airway presents unique anatomic and physiologic challenges that affect anesthetic outcomes, and despite recent advances in difficult airway management, failed intubation/ventilation remains an important cause of general anaesthesia-related morbidity and mortality in pregnant women [<xref rid="ref1" ref-type="bibr">1</xref>, <xref rid="ref2" ref-type="bibr">2</xref>]. In the United States, the case fatality rate for general anesthesia administered for cesarean delivery was estimated at 6.5 per million anesthetics [<xref rid="ref3" ref-type="bibr">3</xref>], while in low- and middle-income countries, approximately one in seven maternal deaths during or following cesarean section were attributed to anesthesia, mostly general anesthesia [<xref rid="ref4" ref-type="bibr">4</xref>]. A UK national survey of the incidence of failed tracheal intubation during obstetric general anesthesia reported a rate of 1 in 224 [<xref rid="ref5" ref-type="bibr">5</xref>]. In 2015, Kinsella et al. [<xref rid="ref6" ref-type="bibr">6</xref>] reported that the incidence of failed tracheal intubation has remained stable over the past 4 decades at 2.6 (1 in 390) and 2.3 (1 in 443) per 1000 anesthetics for obstetric general anesthesia and cesarean section, respectively. In a recent multicentre study involving approximately 14,000 general anesthetics for cesarean delivery, the overall risks of difficult and failed intubation were reported as 1:49 and 1:808, respectively [<xref rid="ref7" ref-type="bibr">7</xref>]. In comparison, the incidence of difficult and failed intubation in the general surgical population was estimated at 1:385 and 1:2230 patients, respectively [<xref rid="ref8" ref-type="bibr">8</xref>, <xref rid="ref9" ref-type="bibr">9</xref>]. Maternal death from failed intubation in cesarean delivery was estimated at 1 per 90 failed intubations or 2.3 per 100,000 general anesthetics, with aspiration and hypoxemia being the leading cause of mortality [<xref rid="ref6" ref-type="bibr">6</xref>]. Failed intubation was also an independent predictor of neonatal intensive care unit admission [<xref rid="ref6" ref-type="bibr">6</xref>].</p>
</sec>
<sec id="sec2"><title>Peculiarities of the obstetric airway</title>
<p>The physiologic and anatomic changes related to pregnancy affect oxygenation and airway management [<xref rid="ref2" ref-type="bibr">2</xref>], and the presence of co-existing morbidities, such as obesity or preeclampsia, may further complicate anesthetic care. Upper airway edema and friability in pregnancy decrease the pharyngolaryngeal tract diameter, reduce airway compliance and increase the risk of mucosal bleeding and difficulty in passing the endotracheal tube [<xref rid="ref10 ref11 ref12 ref13" ref-type="bibr">10&#x2013;13</xref>]. Fluid retention and weight gain correlate with an increase in the Mallampati score [<xref rid="ref14" ref-type="bibr">14</xref>]. Reduction in functional residual capacity combined with a rise in oxygen consumption at term and in labor lowers the oxygen reserve, accelerating the occurrence of oxygen desaturation during hypoventilation and apnoea [<xref rid="ref10" ref-type="bibr">10</xref>, <xref rid="ref15" ref-type="bibr">15</xref>]. In addition, pregnancy is associated with decreased gastric emptying, gastric pH, and gastro-esophageal sphincter competence and increased intragastric pressure and risk of inhalation of gastric contents [<xref rid="ref10" ref-type="bibr">10</xref>, <xref rid="ref13" ref-type="bibr">13</xref>].</p>
<p>On the other hand, the incidence of airway management complications is likely to escalate with the declining trend of experience and skills in obstetric general anesthesia. The bulk of &#x201C;first on&#x201D; obstetric anesthetic cover is often provided by specialist registrars, senior house officers, and non-trainees with limited exposure and experience in obstetric general anesthesia, mostly in the context of obstetric emergencies and often outside of regular working hours [<xref rid="ref16 ref17 ref18" ref-type="bibr">16&#x2013;18</xref>]. Besides, obstetric operating rooms are often remotely located and may not always have the resources necessary to handle a difficult airway [<xref rid="ref19" ref-type="bibr">19</xref>]. In smaller, understaffed obstetric units, there may be a higher likelihood of inadequate clinical or equipment preparedness and assessment under emergency circumstances.</p>
<p>Several studies have attempted to characterize the risk factors for failed or difficult intubation in the parturient. Reale et al. [<xref rid="ref7" ref-type="bibr">7</xref>] found that non-obstetric factors, such as increased body mass index (BMI), Mallampati score III or IV, short hyoid-to-mentum distance, and limited jaw protrusion, mouth opening, and cervical spine accounted for most of the risk factors for intubation difficulties in parturients. A UK survey similarly reported that failed tracheal intubation was independently predicted by age, BMI, and a documented Mallampati score [<xref rid="ref5" ref-type="bibr">5</xref>]. The incidence of failed intubations was found to be disproportionately higher in Asians and Africans/Afro-Caribbeans, reflecting the increased use of general anesthesia in these patients [<xref rid="ref16" ref-type="bibr">16</xref>], suggesting the importance of racial demographics as a predictive factor. However, in practice, failed or difficult intubation in the parturient is often unpredictable [<xref rid="ref10" ref-type="bibr">10</xref>] because clinical screening tests, such as neck circumference, sternomental distance, the modified Mallampati test, and the ratio of neck circumference to sternomental distance, are of limited predictive value [<xref rid="ref20 ref21 ref22" ref-type="bibr">20&#x2013;22</xref>].</p>
<p>In contrast to common belief [<xref rid="ref8" ref-type="bibr">8</xref>, <xref rid="ref23" ref-type="bibr">23</xref>], several recent studies found no differences in general anesthetic outcomes between obstetric and non-obstetric patients. For example, a retrospective analysis of 2802 obstetric patients from 2010 to 2015 found that regardless of the increase in obesity and the American Society of Anaesthesiologists Physical Status (ASA) scores, the incidence of failed intubation was not increased in obstetric patients [<xref rid="ref24" ref-type="bibr">24</xref>]. Similarly, the incidence of failed intubations was found to be similar in obstetric patients undergoing surgical delivery and non-pregnant female patients undergoing non-obstetric abdominal or gynecologic surgery under general anesthesia [<xref rid="ref25" ref-type="bibr">25</xref>]. Besides methodological differences and limitations, the discrepancies in the literature regarding the incidence of difficult or failed intubation in obstetric versus general population may reflect the improved understanding and management practices for the difficult airway, enhanced clinical screening, and increased use of neuraxial techniques in women with predicted airway difficulty, or institution-specific factors, such as availability of experienced teams and modern equipment, and adherence to standard guidelines [<xref rid="ref1" ref-type="bibr">1</xref>].</p>
<table-wrap id="TB1">
<label>Table 1</label>
<caption>
<p>Categories of videolaryngoscopes</p></caption>
<table frame="hsides" rules="groups">
<colgroup>
<col span="1" align="left"/>
<col span="2" align="left"/>
<col span="3" align="left"/>
</colgroup>
<thead>
<tr valign="bottom">
<th><bold>Type of videolaryngoscope</bold></th>
<th><bold>Description</bold></th>
<th><bold>Examples</bold></th>
</tr>
</thead>
<tbody>
<tr valign="top">
<td>Macintosh-style videolaryngoscope (Macintosh-style VL)</td>
<td>&#x2013; Macintosh-style bladesand video technology&#x2013; Similar insertionprocedure to theMacintosh laryngoscope &#x2013; A tube introducer andlaryngeal pressure areoften needed to clearlyvisualize the glottis</td>
<td>&#x2013; Storz V-MAC &#x2013; C-MAC &#x2013; McGrath MAC</td>
</tr>
<tr valign="top">
<td>Hyperangulated videolaryngoscope (HA-VL)</td>
<td>&#x2013; j-shaped orhyperangulated bladeable to visualize theglottis without flexing orextending the neck &#x2013; Offers an indirect view ofthe glottis, and intubationrequires a pre-shapedstylet &#x2013; Upper airway traumacould occur when the tipis not visible</td>
<td>&#x2013; Glidescope &#x2013; McGrath Series 5 &#x2013; TruView Devices &#x2013; Bullardlaryngoscope &#x2013; Storz D-blade &#x2013; AP Venner scope</td>
</tr>
<tr valign="top">
<td>Channeled-videolaryngoscope (Channeled-VL)</td>
<td>&#x2013; j-shaped orhyperangulated bladewith a canal that guidesthe tracheal tube to theglottis &#x2013; The tube tip is visiblethroughout trachealintubation</td>
<td>&#x2013; Airtraq &#x2013; Pentax-airwayscope</td>
</tr>
</tbody></table></table-wrap></sec>
<sec id="sec3"><title>Background of videolaryngoscopy in obstetrics</title>
<p>Given the peculiarities of the obstetric airway, the emergent nature of the vast majority of obstetric intubations, and the reality that difficult or failed intubation is mostly unpredictable in the parturient, there is a compelling need to reappraise current practices in obstetric airway management. Since Tunstall&#x2019;s landmark guideline on failed obstetric intubation [<xref rid="ref26" ref-type="bibr">26</xref>], several developments have been made to improve the safety of obstetric general anesthesia. One significant development in recent decades is the evolution of the videolaryngoscope (VL).</p>
<p>Initially, introduced in 2001 by Canadian surgeon Dr. John Pacey, the VL is arguably the most significant milestone in tracheal intubation since the invention of the Macintosh laryngoscope approximately 80 years ago. A VL is a laryngoscope equipped with a high-resolution digital camera located a few centimeters near the tip of a blade and a means of transmitting the image to a display, enhancing visualization of the larynx by providing a more anterior view of the glottis and a wider angle of vision [<xref rid="ref1" ref-type="bibr">1</xref>, <xref rid="ref27" ref-type="bibr">27</xref>]. VLs are available in different sizes and blade shapes and may be portable, single-use or reusable, channeled or non-channeled [<xref rid="ref27" ref-type="bibr">27</xref>]. Based on the shape of the blade and other operational mechanisms, three major categories of VLs have been recognized (Macintosh-style VL, hyperangulated [HA]-VL, and channeled VL), as summarized in <xref ref-type="table" rid="TB1">Table 1</xref> [<xref rid="ref1" ref-type="bibr">1</xref>, <xref rid="ref28" ref-type="bibr">28</xref>].</p>
<p>When compared to a direct laryngoscope, the VL offers many benefits. The operator&#x2019;s field of view during direct laryngoscopy is only 10&#x2013;15 degrees, but videolaryngoscopy expands the angle of view to approximately 60&#x2013;80 degrees [<xref rid="ref1" ref-type="bibr">1</xref>], significantly improving the Cormack and Lehane (C/L) grades. Asai et al. [<xref rid="ref29" ref-type="bibr">29</xref>] reported that in all but 1 of 256 patients with C/L grade 3 or 4 with the Macintosh laryngoscope, the view with the Pentax-AWS<sup>&#x00AE;</sup>-VL was either grade 1 or 2. Patients with cervical spine immobilization benefit greatly from the VL because its video camera eliminates the requirement for aligning the three airway axis and delivers a superior glottic view with less strain and cervical spine manipulation [<xref rid="ref27" ref-type="bibr">27</xref>, <xref rid="ref30" ref-type="bibr">30</xref>, <xref rid="ref31" ref-type="bibr">31</xref>]. The shared airway view provided by VL facilitates teamwork, communication, and teaching during intubation and other aspects of airway care and substantially improves the margin of safety in airway management [<xref rid="ref27" ref-type="bibr">27</xref>]. Furthermore, the study of Vuolato et al. [<xref rid="ref32" ref-type="bibr">32</xref>], which investigated the differences in subjective and objective cognitive workload between HA-VL (Glidescope) versus direct laryngoscopy in a real clinical setting found that a videolaryngoscopy significantly reduced both measures; hence, proficiency with HA-VL constitutes an ergonomic option that could limit operators&#x2019; workload and improve patients&#x2019; safety. The Cochrane meta-analysis of Hansel et al. [<xref rid="ref33" ref-type="bibr">33</xref>], which included more than 200 randomized controlled trials and more than 26,000 patients, concluded that VLs of any design reduce the rates of failed intubation and increase the rates of successful first-attempt intubation. Garcia et al. [<xref rid="ref34" ref-type="bibr">34</xref>] studied first-attempt intubation success among emergency medicine trainees by laryngoscopic device and training year and found that each laryngoscopy device class was associated with improvement in first-attempt success as training progressed. The VL outperformed the direct laryngoscope for all operator groups, and postgraduate year-1 trainees achieved higher first-attempt success using a Macintosh style-VL than postgraduate year-3&#x002B; trainees using a direct laryngoscope. The authors supported the suggestion that a direct laryngoscope should not be routinely used for the first intubation attempt in adult patients unless clinical circumstances would favor its success [<xref rid="ref34" ref-type="bibr">34</xref>]. Sakles et al. studied almost 2000 patients in their emergency department and reported a higher first-pass success intubation rate when using a GlideScope<sup>&#x00AE;</sup>-VL with an HA-blade in either a clean (91%) or soiled (81%) airway, compared with direct laryngoscope, with which first-pass success was 76% in a clean and 66% in a soiled airway. Therefore, whilst soiling of the airway reduced first-pass success by approximately 10% with both devices, the relative efficacy of videolaryngoscopy increased and was 21% more likely to achieve first-pass success in the clean airway and 24% more likely in the soiled airway [<xref rid="ref35" ref-type="bibr">35</xref>].</p>
<p>Despite the aforementioned advantages of videolaryngoscopy, several limitations have been noted. In real-world airway management in obstetrics, a recent large observational study by Odor et al. [<xref rid="ref36" ref-type="bibr">36</xref>] highlighted an alarmingly low adoption of videolaryngoscopy (1.9%). One important drawback is that a successful tracheal tube insertion is not always guaranteed, even when a C/L grade 1 view is demonstrated [<xref rid="ref37" ref-type="bibr">37</xref>]. This phenomenon has been described as &#x201C;laryngoscopy paradox&#x201D; [<xref rid="ref38" ref-type="bibr">38</xref>], predominantly associated with the use of HA-VL due to poor insertion technique in the vast majority of cases. Moreover, the presence of airway pathology, a history of airway surgery or neck radiotherapy, the presence of a cervical collar, and a restricted cervical range of motion are all variables that have been linked to failed videolaryngoscopy [<xref rid="ref30" ref-type="bibr">30</xref>]. In addition, technical issues, like monitor malfunction, low battery power, solar glare, fogging, and the presence of fluids like blood or secretions in the airway, may blur or obscure the video screen image and, consequently, complicate intubation [<xref rid="ref27" ref-type="bibr">27</xref>]. Perforation or laceration injuries to the palatopharyngeal wall, soft palate, and tonsillar pillar have been described with videolaryngoscopy [<xref rid="ref39 ref40 ref41" ref-type="bibr">39&#x2013;41</xref>], most likely associated with poor training/technique.</p>
<p>Several clinical recommendations have been proposed for improving techniques of videolaryngoscopy [<xref rid="ref42" ref-type="bibr">42</xref>]. The HA-VL may be placed into the patient&#x2019;s mouth either in the midline or along the right side of the tongue, watching the blade tip as it enters the mouth and continuing to monitor it on the VL screen after it disappears from view. Optimizing the laryngeal view by mentally dividing the VL screen into a 3 &#x00D7; 3 grid of 9 rectangles and locating the vocal cords in the center rectangle is crucial. Using a prefabricated stylet, a curved malleable stylet, or a stylet that can be &#x201C;activated&#x201D; into a curved shape, the tracheal tube should be fashioned into a shape that roughly resembles the curvature of the HA-VL. A tracheal tube half a size smaller than normal should be used, and a reinforced straight tracheal tube may be appropriate. Lubricant should be applied to the stylet and the end of the tracheal tube. When the tip of the tracheal tube is moved along the hyperangulated blade, it will consistently and effortlessly pass to the location the camera is pointed (i.e., into the glottis). This eliminates the potential for injury of the pharyngeal wall caused by a blind spot. As the stylet tube is advanced to the glottis, the stylet should be retracted. When advancing the tracheal tube, if there is any resistance, it can be turned 30&#x2013;45 degrees clockwise or counterclockwise. Intubation with a bougie is not advised since the device unfurls too quickly, increasing the likelihood of a botched procedure due to insufficient curvature [<xref rid="ref42" ref-type="bibr">42</xref>]. A simplified airway management algorithm has been introduced to facilitate the clinical adaptation of VL and the teaching of protocol to novices [<xref rid="ref43" ref-type="bibr">43</xref>]. In the absence of a predicted difficult airway which dictates the use of HA-VL, the Macintosh-style VL is suggested as a primary intubation device as it offers the benefits of videolaryngoscopy and direct laryngoscopy [<xref rid="ref44" ref-type="bibr">44</xref>]. Meanwhile, considering the great diversity of VL models, it may be prudent that each institution selects one or a maximum of two models of VLs to limit the challenges associated with the multiplicity of devices.</p>
<sec id="sec3a"><title>Videolaryngoscopy vs direct laryngoscopy in obstetrics: Comparison of primary outcomes</title>
<p>Much of the current evidence on the use of videolaryngoscopy in obstetrics derives from the considerable experience and the broad spectrum of studies in non-obstetric airway management [<xref rid="ref45" ref-type="bibr">45</xref>]. An extensive literature search was performed on Medline (PubMed) using different combinations of keywords and vocabulary terms related to the subject of the review (including <italic>obstetrics</italic>, <italic>pregnancy</italic>, <italic>videolaryngoscopy</italic>, <italic>intubation</italic>, and <italic>general anesthesia</italic>). The following search criteria were applied: full-text-accessible articles, articles in English, peer-reviewed original research reports or relevant systematic reviews, without restriction to the year of publication. Additional literature was sourced by examining the reference lists of all studies extracted from the database search. Altogether, the literature search yielded a limited body of studies that specifically examined the use of videolaryngoscopy in the obstetric population, with a preponderance of case reports/series and observational studies. A few randomized control trials evaluated some clinical outcomes in the application of videolaryngoscopy in obstetrics [<xref rid="ref46 ref47 ref48" ref-type="bibr">46&#x2013;48</xref>]. Superior glottic visualization higher (percentage of glottic opening [POGO]) value and favorable C/L grade was demonstrated with different VL models compared to the Macintosh laryngoscope in orotracheal intubation [<xref rid="ref46" ref-type="bibr">46</xref>, <xref rid="ref48" ref-type="bibr">48</xref>]. However, a recent meta-analysis of three randomized-controlled trials involving obstetric patients without difficult airways demonstrated no disparity between videolaryngoscopy and direct laryngoscopy regarding first-attempt success rate and time to tracheal intubation [<xref rid="ref49" ref-type="bibr">49</xref>].</p>
<p>In a retrospective analysis of 180 obstetric intubations, Aziz et al. reported that first-pass intubation was successful in 157 of 163 patients (95% CI 92%&#x2013;99%) using a direct laryngoscope, while first-attempt intubation was successful in 18 of 18 cases (95% CI 81%&#x2013;100%) with videolaryngoscopy, with most patients managed by videolaryngoscopy exhibiting predictive features of a difficult airway. However, the findings of this study should be interpreted cautiously, given that the incidence of failed intubation was not large enough to conclude whether videolaryngoscopy improves outcomes [<xref rid="ref50" ref-type="bibr">50</xref>]. Similarly, an observational study of 100 intubations in an obstetric unit reported that videolaryngoscopy was the modality of choice in two-thirds of cases, and successful intubation was recorded in all cases [<xref rid="ref51" ref-type="bibr">51</xref>]. In addition, several case reports have also described the successful use of videolaryngoscopy in the setting of difficult airways or as a rescue modality following failed direct laryngoscopy in parturients with challenging airways [<xref rid="ref52 ref53 ref54 ref55" ref-type="bibr">52&#x2013;55</xref>].</p>
<p>In patients undergoing elective cesarean section under general anesthesia, it was found that hemodynamic parameters were better preserved in the first three minutes with the GlideScope<sup>&#x00AE;</sup>-VL compared to the Macintosh direct laryngoscope, although other outcome measures (Mallampati score, sore throat, Apgar scores, and hemodynamic changes after three minutes) were similar in both groups [<xref rid="ref47" ref-type="bibr">47</xref>]. It has similarly been suggested that videolaryngoscopy may be associated with more attenuated sympathetic response in hypertensive obstetric patients [<xref rid="ref56" ref-type="bibr">56</xref>].</p>
<p>A randomized comparison of two VL models (C-MAC and King Vision<sup>&#x00AE;</sup>) for obstetric intubation noted that while both models did not differ from direct laryngoscopes regarding time to intubation, the C-MAC-VL may be preferable for obstetric intubations due to favorable performance indices such as ease of use and less need for optimization maneuvers [<xref rid="ref48" ref-type="bibr">48</xref>].</p>
</sec></sec>
<sec id="sec4"><title>Current practice guidelines recommendations on the role of videolaryngoscopy in obstetrics</title>
<p>Until recently, there has been a consistent failure to recognize the peculiarities of the obstetric airway in most of the major airway management guidelines. For example, in the Task Force guidelines for the management of the difficult airway by the Difficult Airway Society UK (DAS) and American Society of Anaesthesiologists (ASA), no specific consideration was accorded to the obstetric patient [<xref rid="ref2" ref-type="bibr">2</xref>]. The 2022 ASA Practice Guideline for Management of the Difficult Airway [<xref rid="ref57" ref-type="bibr">57</xref>] extensively reviewed the published randomized-controlled trials on the use of the videolaryngoscopy in airway management, and reported Category A1-B evidence that videolaryngoscopy was superior to direct laryngoscopy with regard to laryngeal views, the success rate for intubation, rate of first attempt intubation, and the number of intubation manoeuvres; with equivocal findings for time to intubation (Category A1-E evidence). The obstetric population was not explicitly considered in the analysis and report of the current evidence.</p>
<p>However, in recent years, tailored guidelines for airway management in obstetrics have emerged. The Obstetric Anaesthetists&#x2019; Association and Difficult Airway Society Guideline for the Management of Difficult and Failed Tracheal Intubation in Obstetrics [<xref rid="ref2" ref-type="bibr">2</xref>] is perhaps the most widely referenced of the tailored obstetric guidelines. The Guidelines recommend that &#x201C;a VL should be immediately available for all obstetric general anesthetics.&#x201D; Nevertheless, it also points out several current limitations, including the lack of reliable comparative studies on the most suitable VL model for obstetric intubation, the phenomenon of &#x201C;laryngoscopy paradox,&#x201D; and reports of traumatic laryngoscopy, especially with stylet devices.</p>
<p>The All-India Difficult Airway Association 2016 Guidelines for the Management of Unanticipated Difficult Tracheal Intubation in Obstetrics [<xref rid="ref58" ref-type="bibr">58</xref>] recommends that in accordance with local practice and expertise, laryngoscopy may be performed with either a direct laryngoscope or a VL. The Guidelines, however, recommend that in the event of an unsuccessful first attempt, &#x201C;the second attempt at laryngoscopy should be performed using a VL, alternate blades and use of a bougie as dictated by the availability of equipment and expertise.&#x201D; Using a VL in such a situation allows the assistant to gradually decrease cricoid pressure while monitoring the effect on the laryngoscope&#x2019;s field of view [<xref rid="ref58" ref-type="bibr">58</xref>]. However, if tracheal intubation on the first attempt using a direct laryngoscope is difficult, one will have &#x201C;wasted&#x201D; an attempt that might have been more easily salvaged with a Macintosh-like VL &#x002B;/&#x2013; adjunct by just looking at the screen after using it as a direct laryngoscope. In a comparative analysis of commonly used rescue intubation techniques after failed direct laryngoscopy, Aziz et al. [<xref rid="ref59" ref-type="bibr">59</xref>] reported a high rescue intubation success rate with videolaryngoscopy. However, the retrospective observational nature of this study should be considered in interpreting the frequency of airway rescue and the rescue success rates reported [<xref rid="ref59" ref-type="bibr">59</xref>].</p>
</sec>
<sec id="sec5"><title>Challenges of clinical adoption of videolarygoscopy in obstetrics</title>
<p>Besides the already highlighted limitations, such as inconsistencies in comparative clinical outcomes, a few other issues warrant further consideration regarding the routine use of VLs in obstetrics. There is little or no evidence regarding the predictors of difficult videolaryngoscopy in obstetrics, and there is no clear protocol for managing failed videolaryngoscopy [<xref rid="ref27" ref-type="bibr">27</xref>]. The exact factors that facilitate successful tracheal tube insertion with videolaryngoscopy have been insufficiently characterized; hence, improved glottic visualization does not always translate to successful intubation. The multiplicity of VL models with unique operational protocols poses a challenge to learning and uniformity of practice, and the evidence remains limited to guide the rational choice of the appropriate type of device according to indication or context [<xref rid="ref60" ref-type="bibr">60</xref>]. Additionally, the benchmark for expertise and the appropriate pedagogical approach for videolaryngoscopy remains uncertain.</p>
<p>Reports regarding the learning curve for VLs are conflicting. For example, in a prospective trial with 40 intubation-naive medical students in simulated simple and difficult laryngoscopy scenarios, Maharaj et al. [<xref rid="ref61" ref-type="bibr">61</xref>] reported that the Airtraq-VL was associated with a rapid learning curve compared to the Macintosh laryngoscope and, accordingly, appears more suitable for teaching tracheal intubation to novices. In contrast, Cortellazzi et al. [<xref rid="ref62" ref-type="bibr">62</xref>] reported that expertise with the VL was attained after 76 attempts, suggesting that prolonged experience and training were necessary to attain proficiency with the device. Basic intubation competencies appear to be retained over time independent of the laryngoscopic method; however, videolaryngoscopy in the hands of novice operators was associated with quicker intubation and fewer adverse events after three months with no additional intubation training. Additionally, it was shown that while first-attempt success with direct laryngoscope did not increase significantly over the course of residency training, the performance of videolaryngoscopy improved substantially [<xref rid="ref64" ref-type="bibr">64</xref>].</p>
<p>Furthermore, given the proliferation of VL models, each with unique technical properties and operational requirements (e.g., patient positioning, tongue displacement, insertion depth, the direction of applied forces, blade axis, etc.), successful intubation may only be practical with technical competence with each specific device, and familiarity with the use of different devices may require a long learning curve [<xref rid="ref1" ref-type="bibr">1</xref>]. Simply put, expertise with the traditional Macintosh laryngoscope is not transferable to the VL, and mastery of one VL model does not translate to proficiency with other models [<xref rid="ref65" ref-type="bibr">65</xref>]. This particularly applies to the technique required the use of an HA-VL blade, which is completely different from that of a Macintosh-shaped laryngoscope blade. When an intubator gains a good view of the larynx using a hyperangulated blade but fails to use an appropriate technique, it is likely that the intubator and not the device is the cause of the unsuccessful intubation [<xref rid="ref42" ref-type="bibr">42</xref>].</p>
<p>Finally, the enormous cost disparity between VLs and conventional laryngoscopes remarkably restricts the availability and use of the former, especially in the resource-limited settings [<xref rid="ref27" ref-type="bibr">27</xref>]. Although, in recent years, notably since the beginning of the COVID-19 pandemic, there has been an increasing availability of low-cost generic and handcrafted VL models [<xref rid="ref66" ref-type="bibr">66</xref>, <xref rid="ref67" ref-type="bibr">67</xref>]. There are concerns regarding quality and evidence for their comparability with validated models is limited. On the other hand, a broader consideration of the health economics of videolaryngoscopy use in surgical settings has shown that, in reality, it may be associated with a reduction in the total cost of inpatient care, the length of hospital stay, and the odds of procedural complications and intensive care unit admission [<xref rid="ref68" ref-type="bibr">68</xref>]. Accordingly, equipment and training costs may be substantially buffered by overall reductions in healthcare costs that may be associated with the adoption of videolaryngoscopy. Moreover, the COVID-19 pandemic has increased awareness of the risk involved in managing the airway with conventional laryngoscopy, which may contribute to overcoming previous reluctance to the routine use of videolaryngoscopy [<xref rid="ref69" ref-type="bibr">69</xref>].</p>
</sec>
<sec id="sec6"><title>Conclusion</title>
<p>Videolaryngoscopy enhances glottic visualization, increases the odds of successful intubation, and promotes team communication and teaching during intubation. In cases of unexpected or difficult airway, or unsuccessful direct laryngoscopy, videolaryngoscopy has proven effective [<xref rid="ref28" ref-type="bibr">28</xref>]. Considering the anatomical and physiological peculiarities of the obstetric airway, the poor predictive value of routine airway clinical assessment tests, and the fact that most obstetric intubations occur in emergency settings, it may be prudent to assume that most obstetric intubations will be difficult, and VL provides compelling advantages in this regard. The Macintosh-style VL can be suggested as a primary intubation device as it offers the benefits of videolaryngoscopy and direct laryngoscopy. However, more rigorous evidence is urgently needed to clarify the current blind spots and controversies regarding the use of videolaryngoscopy in obstetrics and other clinical settings.</p>
</sec>
</body>
<back>
<ref-list>
<title>References</title>
<ref id="ref1">
<label>1</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Scott-Brown</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Russell</surname>
<given-names>R</given-names>
</name>
</person-group> 
<article-title>Video laryngoscopes and the obstetric airway</article-title>
<source>Int J Obstet Anesth</source> <year>2015 May</year> <volume>24</volume>
<issue>2</issue>
<fpage>137</fpage>
<lpage>46</lpage>
<comment>https://doi.org/10.1016/j.ijoa.2015.01.005</comment>
</element-citation>
</ref>
<ref id="ref2">
<label>2</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mushambi</surname>
<given-names>MC</given-names>
</name>
<name>
<surname>Kinsella</surname>
<given-names>SM</given-names>
</name>
<name>
<surname>Popat</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Swales</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Ramaswamy</surname>
<given-names>KK</given-names>
</name>
<name>
<surname>Winton</surname>
<given-names>AL</given-names>
</name> <etal/>
</person-group> 
<article-title>Obstetric anaesthetists&#x2019; association and difficult airway society guidelines for the management of difficult and failed tracheal intubation in obstetrics</article-title>
<source>Anaesthesia</source> <year>2015 Nov</year> <volume>70</volume>
<issue>11</issue>
<fpage>1286</fpage>
<lpage>306</lpage>
<comment>https://doi.org/10.1111/anae.13260</comment>
</element-citation>
</ref>
<ref id="ref3">
<label>3</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hawkins</surname>
<given-names>JL</given-names>
</name>
<name>
<surname>Chang</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Palmer</surname>
<given-names>SK</given-names>
</name>
<name>
<surname>Gibbs</surname>
<given-names>CP</given-names>
</name>
<name>
<surname>Callaghan</surname>
<given-names>WM</given-names>
</name>
</person-group> 
<article-title>Anesthesia-related maternal mortality in the United States: 1979&#x2013;2002</article-title>
<source>Obstet Gynecol</source> <year>2011 Jan</year> <volume>117</volume>
<issue>1</issue>
<fpage>69</fpage>
<lpage>74</lpage>
<comment>https://doi.org/10.1097/AOG.0b013e31820093a9</comment>
</element-citation>
</ref>
<ref id="ref4">
<label>4</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sobhy</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Zamora</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Dharmarajah</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Arroyo-Manzano</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Wilson</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Navaratnarajah</surname>
<given-names>R</given-names>
</name> <etal/>
</person-group> 
<article-title>Anaesthesia-related maternal mortality in low-income and middle-income countries: a systematic review and meta-analysis</article-title>
<source>Lancet Glob Health</source> <year>2016 May</year> <volume>4</volume>
<issue>5</issue>
<fpage>e320</fpage>
<lpage>7</lpage>
<comment>https://doi.org/10.1016/S2214-109X(16)30003-1</comment>
</element-citation>
</ref>
<ref id="ref5">
<label>5</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Quinn</surname>
<given-names>AC</given-names>
</name>
<name>
<surname>Milne</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Columb</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Gorton</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Knight</surname>
<given-names>M</given-names>
</name>
</person-group> 
<article-title>Failed tracheal intubation in obstetric anaesthesia: 2 yr national case&#x2013;control study in the UK</article-title>
<source>Br J Anaesth</source> <year>2013</year>
<volume>110</volume>
<issue>1</issue>
<fpage>74</fpage>
<lpage>80</lpage>
<comment>https://doi.org/10.1093/bja/aes320</comment>
</element-citation>
</ref>
<ref id="ref6">
<label>6</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kinsella</surname>
<given-names>SM</given-names>
</name>
<name>
<surname>Winton</surname>
<given-names>AL</given-names>
</name>
<name>
<surname>Mushambi</surname>
<given-names>MC</given-names>
</name>
<name>
<surname>Ramaswamy</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Swales</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Quinn</surname>
<given-names>AC</given-names>
</name> <etal/>
</person-group> 
<article-title>Failed tracheal intubation during obstetric general anaesthesia: a literature review</article-title>
<source>Int J Obstet Anesth</source> <year>2015 Nov</year> <volume>24</volume>
<issue>4</issue>
<fpage>356</fpage>
<lpage>74</lpage>
<comment>https://doi.org/10.1016/j.ijoa.2015.06.008</comment>
</element-citation>
</ref>
<ref id="ref7">
<label>7</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Reale</surname>
<given-names>SC</given-names>
</name>
<name>
<surname>Bauer</surname>
<given-names>ME</given-names>
</name>
<name>
<surname>Klumpner</surname>
<given-names>TT</given-names>
</name>
<name>
<surname>Aziz</surname>
<given-names>MF</given-names>
</name>
<name>
<surname>Fields</surname>
<given-names>KG</given-names>
</name>
<name>
<surname>Hurwitz</surname>
<given-names>R</given-names>
</name> <etal/>
</person-group> 
<article-title>Frequency and risk factors for difficult intubation in women undergoing general anesthesia for cesarean delivery: a multicenter retrospective cohort analysis</article-title>
<source>Anesthesiology</source> <year>2022 May</year> <volume>136</volume>
<issue>5</issue>
<fpage>697</fpage>
<lpage>708</lpage>
<comment>https://doi.org/10.1097/ALN.0000000000004173</comment>
</element-citation>
</ref>
<ref id="ref8">
<label>8</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Samsoon</surname>
<given-names>GLT</given-names>
</name>
<name>
<surname>Young</surname>
<given-names>JRB</given-names>
</name>
</person-group> 
<article-title>Difficult tracheal intubation: a retrospective study</article-title>
<source>Anaesthesia</source> <year>1987</year>
<volume>42</volume>
<issue>5</issue>
<fpage>487</fpage>
<lpage>90</lpage>
<comment>https://doi.org/10.1111/j.1365-2044.1987.tb04039.x</comment>
</element-citation>
</ref>
<ref id="ref9">
<label>9</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Jayaraj</surname>
<given-names>AK</given-names>
</name>
<name>
<surname>Siddiqui</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Abdelghany</surname>
<given-names>SMO</given-names>
</name>
<name>
<surname>Balki</surname>
<given-names>M</given-names>
</name>
</person-group> 
<article-title>Management of difficult and failed intubation in the general surgical population: a historical cohort study in a tertiary care centre</article-title>
<source>Can J Anaesth</source> <year>2022 Apr</year> <volume>69</volume>
<issue>4</issue>
<fpage>427</fpage>
<lpage>37</lpage>
<comment>https://doi.org/10.1007/s12630-021-02161-5</comment>
</element-citation>
</ref>
<ref id="ref10">
<label>10</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Vasdev</surname>
<given-names>GM</given-names>
</name>
<name>
<surname>Harrison</surname>
<given-names>BA</given-names>
</name>
<name>
<surname>Keegan</surname>
<given-names>MT</given-names>
</name>
<name>
<surname>Burkle</surname>
<given-names>CM</given-names>
</name>
</person-group> 
<article-title>Management of the difficult and failed airway in obstetric anesthesia</article-title>
<source>J Anesthesia</source> <year>2008 Feb</year> <volume>22</volume>
<issue>1</issue>
<fpage>38</fpage>
<lpage>48</lpage>
<comment>https://doi.org/10.1007/s00540-007-0577-z</comment>
</element-citation>
</ref>
<ref id="ref11">
<label>11</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Jouppila</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Jouppila</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Hollm&#x00E9;n</surname>
<given-names>A</given-names>
</name>
</person-group> 
<article-title>Laryngeal oedema as an obstetric anaesthesia complication: case reports</article-title>
<source>Acta Anaesthesiol Scand</source> <year>1980</year>
<volume>24</volume>
<issue>2</issue>
<fpage>97</fpage>
<lpage>8</lpage>
<comment>https://doi.org/10.1111/j.1399-6576.1980.tb01514.x</comment>
</element-citation>
</ref>
<ref id="ref12">
<label>12</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Brock-Utne</surname>
<given-names>JG</given-names>
</name>
<name>
<surname>Downing</surname>
<given-names>JW</given-names>
</name>
<name>
<surname>Seedat</surname>
<given-names>F</given-names>
</name>
</person-group> 
<article-title>Laryngeal oedema associated with pre-eclamptic toxaemia</article-title>
<source>Anaesthesia</source> <year>1977</year>
<volume>32</volume>
<issue>6</issue>
<fpage>556</fpage>
<lpage>8</lpage>
<comment>https://doi.org/10.1111/j.1365-2044.1977.tb10004.x</comment>
</element-citation>
</ref>
<ref id="ref13">
<label>13</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Boutonnet</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Faitot</surname>
<given-names>V</given-names>
</name>
<name>
<surname>Ke&#x00EF;ta</surname>
<given-names>H</given-names>
</name>
</person-group> 
<article-title>Airway management in obstetrics</article-title>
<source>Ann Fr Anesth Reanim</source> <year>2011 Sep</year> <volume>30</volume>
<issue>9</issue>
<fpage>651</fpage>
<lpage>64</lpage>
<comment>https://doi.org/10.1016/j.annfar.2011.03.024</comment>
</element-citation>
</ref>
<ref id="ref14">
<label>14</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pilkington</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Carli</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Dakin</surname>
<given-names>MJ</given-names>
</name>
<name>
<surname>Romney</surname>
<given-names>M</given-names>
</name>
<name>
<surname>de Witt</surname>
<given-names>KA</given-names>
</name>
<name>
<surname>Dore</surname>
<given-names>CJ</given-names>
</name> <etal/>
</person-group> 
<article-title>Increase in mallampati score during pregnancy</article-title>
<source>Br J Anaesth</source> <year>1995</year>
<volume>74</volume>
<issue>6</issue>
<fpage>638</fpage>
<lpage>42</lpage>
<comment>https://doi.org/10.1093/bja/74.6.638</comment>
</element-citation>
</ref>
<ref id="ref15">
<label>15</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Archer</surname>
<given-names>GW</given-names>
</name>
<name>
<surname>Marx</surname>
<given-names>GF</given-names>
</name>
</person-group> 
<article-title>Arterial oxygen tension during apnoea in parturient women</article-title>
<source>Br J Anaesth</source> <year>1974 May</year> <volume>46</volume>
<issue>5</issue>
<fpage>358</fpage>
<lpage>60</lpage>
<comment>https://doi.org/10.1093/bja/46.5.358</comment>
</element-citation>
</ref>
<ref id="ref16">
<label>16</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hawthorne</surname>
<given-names>L</given-names>
</name>
<name>
<surname>Wilson</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Lyons</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Dresner</surname>
<given-names>M</given-names>
</name>
</person-group> 
<article-title>Failed intubation revisited: 17-yr experience in a teaching maternity unit</article-title>
<source>Br J Anaesth</source> <year>1996</year>
<volume>76</volume>
<issue>5</issue>
<fpage>680</fpage>
<lpage>4</lpage>
<comment>https://doi.org/10.1093/bja/76.5.680</comment>
</element-citation>
</ref>
<ref id="ref17">
<label>17</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Rahman</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Jenkins</surname>
<given-names>JG</given-names>
</name>
</person-group> 
<article-title>Failed tracheal intubation in obstetrics: no more frequent but still managed badly</article-title>
<source>Anaesthesia</source> <year>2005 Feb</year> <volume>60</volume>
<issue>2</issue>
<fpage>168</fpage>
<lpage>71</lpage>
<comment>https://doi.org/10.1111/j.1365-2044.2004.04069.x</comment>
</element-citation>
</ref>
<ref id="ref18">
<label>18</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>McDonnell</surname>
<given-names>NJ</given-names>
</name>
<name>
<surname>Paech</surname>
<given-names>MJ</given-names>
</name>
<name>
<surname>Clavisi</surname>
<given-names>OM</given-names>
</name>
<name>
<surname>Scott</surname>
<given-names>KL</given-names>
</name>
</person-group> 
<article-title>Difficult and failed intubation in obstetric anaesthesia: an observational study of airway management and complications associated with general anaesthesia for caesarean section</article-title>
<source>Int J Obstet Anesth</source> <year>2008 Oct</year> <volume>17</volume>
<issue>4</issue>
<fpage>292</fpage>
<lpage>7</lpage>
<comment>https://doi.org/10.1016/j.ijoa.2008.01.017</comment>
</element-citation>
</ref>
<ref id="ref19">
<label>19</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Bullough</surname>
<given-names>AS</given-names>
</name>
<name>
<surname>Carraretto</surname>
<given-names>M</given-names>
</name>
</person-group> 
<article-title>A United Kingdom national obstetric intubation equipment survey</article-title>
<source>Int J Obstet Anesth</source> <year>2009 Oct</year> <volume>18</volume>
<issue>4</issue>
<fpage>342</fpage>
<lpage>5</lpage>
<comment>https://doi.org/10.1016/j.ijoa.2009.01.015</comment>
</element-citation>
</ref>
<ref id="ref20">
<label>20</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Eiamcharoenwit</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Itthisompaiboon</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Limpawattana</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Suwanpratheep</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Siriussawakul</surname>
<given-names>A</given-names>
</name>
</person-group> 
<article-title>The performance of neck circumference and other airway assessment tests for the prediction of difficult intubation in obese parturients undergoing cesarean delivery</article-title>
<source>Int J Obstet Anesth</source> <year>2017 May</year> <volume>31</volume>
<fpage>45</fpage>
<lpage>50</lpage>
<comment>https://doi.org/10.1016/j.ijoa.2017.01.011</comment>
</element-citation>
</ref>
<ref id="ref21">
<label>21</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>D&#x00ED;az-G&#x00F3;mez</surname>
<given-names>JL</given-names>
</name>
<name>
<surname>Satyapriya</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Satyapriya</surname>
<given-names>SV</given-names>
</name>
<name>
<surname>Mascha</surname>
<given-names>EJ</given-names>
</name>
<name>
<surname>Yang</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Krakovitz</surname>
<given-names>P</given-names>
</name> <etal/>
</person-group> 
<article-title>Standard clinical risk factors for difficult laryngoscopy are not independent predictors of intubation success with the GlideScope</article-title>
<source>J Clin Anesth</source> <year>2011 Dec</year> <volume>23</volume>
<issue>8</issue>
<fpage>603</fpage>
<lpage>10</lpage>
<comment>https://doi.org/10.1016/j.jclinane.2011.03.006</comment>
</element-citation>
</ref>
<ref id="ref22">
<label>22</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Roth</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Pace</surname>
<given-names>NL</given-names>
</name>
<name>
<surname>Lee</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Hovhannisyan</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Warenits</surname>
<given-names>AM</given-names>
</name>
<name>
<surname>Arrich</surname>
<given-names>J</given-names>
</name> <etal/>
</person-group> 
<article-title>Airway physical examination tests for detection of difficult airway management in apparently normal adult patients</article-title>
<source>Cochrane Database Syst Rev</source> <year>2018 May</year> <volume>5</volume>
<issue>5</issue>
<fpage>CD008874</fpage>
<comment>https://doi.org/10.1002/14651858.CD008874</comment>
</element-citation>
</ref>
<ref id="ref23">
<label>23</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ende</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Varelmann</surname>
<given-names>D</given-names>
</name>
</person-group> 
<article-title>Respiratory considerations including airway and ventilation issues in critical care obstetric patients</article-title>
<source>Obstet Gynecol Clin North Am</source> <year>2016 Dec</year> <volume>43</volume>
<issue>4</issue>
<fpage>699</fpage>
<lpage>708</lpage>
<comment>https://doi.org/10.1016/j.ogc.2016.07.002</comment>
</element-citation>
</ref>
<ref id="ref24">
<label>24</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pollard</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Wagner</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Grichnik</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Clyne</surname>
<given-names>BC</given-names>
</name>
<name>
<surname>Habib</surname>
<given-names>AS</given-names>
</name>
</person-group> 
<article-title>Prevalence of difficult intubation and failed intubation in a diverse obstetric community-based population</article-title>
<source>Curr Med Res Opin</source> <year>2017 Dec</year> <volume>33</volume>
<issue>12</issue>
<fpage>2167</fpage>
<lpage>71</lpage>
<comment>https://doi.org/10.1080/03007995.2017.1354289</comment>
</element-citation>
</ref>
<ref id="ref25">
<label>25</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Heinrich</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Irouschek</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Prottengeier</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Ackermann</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Schmidt</surname>
<given-names>J</given-names>
</name>
</person-group> 
<article-title>Adverse airway events in parturient compared with non-parturient patients. is there a difference? Results from a quality management project</article-title>
<source>J Obstet Gynaecol Res</source> <year>2015</year>
<volume>41</volume>
<issue>7</issue>
<fpage>1032</fpage>
<lpage>9</lpage>
<comment>https://doi.org/10.1111/jog.12677</comment>
</element-citation>
</ref>
<ref id="ref26">
<label>26</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Tunstall</surname>
<given-names>ME</given-names>
</name>
</person-group> 
<article-title>Failed intubation in the parturient</article-title>
<source>Can J Anaesth</source> <year>1989 Nov</year>
<volume>36</volume>
<issue>6</issue>
<fpage>611</fpage>
<lpage>3</lpage>
<comment>https://doi.org/10.1007/BF03005408</comment>
</element-citation>
</ref>
<ref id="ref27">
<label>27</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Myatra</surname>
<given-names>SN</given-names>
</name>
<name>
<surname>Patwa</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Divatia</surname>
<given-names>JV</given-names>
</name>
</person-group> 
<article-title>Videolaryngoscopy for all intubations: is direct laryngoscopy obsolete?</article-title>
<source>Indian J Anaesth</source> <year>2022 Mar</year> <volume>66</volume>
<issue>3</issue>
<fpage>169</fpage>
<comment>https://doi.org/10.4103/ija.ija_234_22</comment>
</element-citation>
</ref>
<ref id="ref28">
<label>28</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Behringer</surname>
<given-names>EC</given-names>
</name>
<name>
<surname>Kristensen</surname>
<given-names>MS</given-names>
</name>
</person-group> 
<article-title>Evidence for benefit vs novelty in new intubation equipment</article-title>
<source>Anaesthesia</source> <year>2011 Dec</year> <volume>66</volume>
<issue>S2</issue>
<fpage>57</fpage>
<lpage>64</lpage>
<comment>https://doi.org/10.1111/j.1365-2044.2011.06935.x</comment>
</element-citation>
</ref>
<ref id="ref29">
<label>29</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Asai</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Liu</surname>
<given-names>EH</given-names>
</name>
<name>
<surname>Matsumoto</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Hirabayashi</surname>
<given-names>Y</given-names>
</name>
<name>
<surname>Seo</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Suzuki</surname>
<given-names>A</given-names>
</name> <etal/>
</person-group> 
<article-title>Use of the pentax-AWS <sup>&#x00AE;</sup> in 293 patients with difficult airways</article-title>
<source>Anesthesiology</source> <year>2009</year>
<volume>110</volume>
<fpage>898</fpage>
<lpage>904</lpage>
<comment>https://doi.org/10.1097/ALN.0b013e31819c45e5</comment>
</element-citation>
</ref>
<ref id="ref30">
<label>30</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Aziz</surname>
<given-names>MF</given-names>
</name>
<name>
<surname>Dillman</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Fu</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Ansgar</surname>
<given-names>M Brambrink</given-names>
</name>
</person-group> 
<article-title>Comparative effectiveness of the C-MAC video laryngoscope versus direct laryngoscopy in the setting of the predicted difficult airway</article-title>
<source>Anesthesiology</source> <year>2012 Mar</year> <volume>116</volume>
<issue>3</issue>
<fpage>629</fpage>
<lpage>36</lpage>
<comment>https://doi.org/10.1097/ALN.0b013e318246ea34</comment>
</element-citation>
</ref>
<ref id="ref31">
<label>31</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Choudhary</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Barai</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Das</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Mukherjee</surname>
<given-names>N</given-names>
</name>
</person-group> 
<article-title>Evaluation of the use of the channeled king vision video laryngoscope in improving glottic visualisation in patients with limited glottic view with the Macintosh laryngoscope: a prospective observational study</article-title>
<source>Indian J Anaesth</source> <year>2021 Dec</year> <volume>65</volume>
<issue>12</issue>
<fpage>874</fpage>
<lpage>9</lpage>
<comment>https://doi.org/10.4103/ija.ija_905_21</comment>
</element-citation>
</ref>
<ref id="ref32">
<label>32</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Vuolato</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Caldiroli</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Orena</surname>
<given-names>EF</given-names>
</name>
</person-group> 
<article-title>Effects of direct laryngoscopy versus Glidescope videolaryngoscopy on subjective and objective measures of cognitive workload: an in-vivo randomized trial</article-title>
<source>Minerva Anestesiol</source> <year>2021 Sep</year> <volume>87</volume>
<issue>9</issue>
<fpage>971</fpage>
<lpage>8</lpage>
<comment>https://doi.org/10.23736/S0375-9393.21.15275-7</comment>
</element-citation>
</ref>
<ref id="ref33">
<label>33</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hansel</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Rogers</surname>
<given-names>AM</given-names>
</name>
<name>
<surname>Lewis</surname>
<given-names>SR</given-names>
</name>
<name>
<surname>Cook</surname>
<given-names>TM</given-names>
</name>
<name>
<surname>Smith</surname>
<given-names>AF</given-names>
</name>
</person-group> 
<article-title>Videolaryngoscopy versus direct laryngoscopy for adults undergoing tracheal intubation: a cochrane systematic review and meta-analysis update</article-title>
<source>Br J Anaesth</source> <year>2022 Oct</year> <volume>129</volume>
<issue>4</issue>
<fpage>612</fpage>
<lpage>23</lpage>
<comment>https://doi.org/10.1016/j.bja.2022.05.027</comment>
</element-citation>
</ref>
<ref id="ref34">
<label>34</label>
<element-citation citation-type="web">
<collab>Garcia SI, Sandefur BJ, Campbell RL, Driver BE, April MD, Carlson JN, et al.</collab>
<comment>First-attempt intubation success among emergency medicine trainees by laryngoscopic device and training year: a national emergency airway registry study. Ann Emerg Med Online ahead of print. <ext-link ext-link-type="uri" xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="https://doi.org/10.1016/j.annemergmed.2022.10.019">https://doi.org/10.1016/j.annemergmed.2022.10.019</ext-link>.</comment>
</element-citation>
</ref>
<ref id="ref35">
<label>35</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sakles</surname>
<given-names>JC</given-names>
</name>
<name>
<surname>Corn</surname>
<given-names>GJ</given-names>
</name>
<name>
<surname>Hollinger</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Arcaris</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Patanwala</surname>
<given-names>AE</given-names>
</name>
<name>
<surname>Mosier</surname>
<given-names>JM</given-names>
</name>
</person-group> 
<article-title>The impact of a soiled airway on intubation success in the emergency department when using the glidescope or the direct laryngoscope</article-title>
<source>Acad Emerg Med</source> <year>2017 May</year> <volume>24</volume>
<issue>5</issue>
<fpage>628</fpage>
<lpage>36</lpage>
<comment>https://doi.org/10.1111/acem.13160</comment>
</element-citation>
</ref>
<ref id="ref36">
<label>36</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Odor</surname>
<given-names>PM</given-names>
</name>
<name>
<surname>Bampoe</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Moonesinghe</surname>
<given-names>SR</given-names>
</name>
<name>
<surname>Andrade</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Pandit</surname>
<given-names>JJ</given-names>
</name>
<name>
<surname>Lucas</surname>
<given-names>DN</given-names>
</name> <etal/>
</person-group> 
<article-title>General anaesthetic and airway management practice for obstetric surgery in England: a prospective, multicentre observational study</article-title>
<source>Anaesthesia</source> <year>2021 Apr</year> <volume>76</volume>
<issue>4</issue>
<fpage>460</fpage>
<lpage>71</lpage>
<comment>https://doi.org/10.1111/anae.15250</comment>
</element-citation>
</ref>
<ref id="ref37">
<label>37</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hwang</surname>
<given-names>SM</given-names>
</name>
</person-group> 
<article-title>A good laryngeal view does not guarantee perfectly successful tracheal intubation</article-title>
<source>Korean J Anesthesiol</source> <year>2016 Apr</year> <volume>69</volume>
<issue>2</issue>
<fpage>111</fpage>
<lpage>2</lpage>
<comment>https://doi.org/10.4097/kjae.2016.69.2.111</comment>
</element-citation>
</ref>
<ref id="ref38">
<label>38</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Stopar Pintaric</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Blajic</surname>
<given-names>I</given-names>
</name>
<name>
<surname>Hodzovic</surname>
<given-names>I</given-names>
</name>
</person-group> 
<article-title>Comparing videolaryngoscopes with direct laryngoscopy in obstetric patients</article-title>
<source>Int J Obstet Anesth</source> <year>2020 Feb</year> <volume>41</volume>
<fpage>119</fpage>
<lpage>20</lpage>
<comment>https://doi.org/10.1016/j.ijoa.2019.07.007</comment>
</element-citation>
</ref>
<ref id="ref39">
<label>39</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Leong</surname>
<given-names>WL</given-names>
</name>
<name>
<surname>Lim</surname>
<given-names>Y</given-names>
</name>
<name>
<surname>Sia</surname>
<given-names>ATH</given-names>
</name>
</person-group> 
<article-title>Palatopharyngeal wall perforation during glidescope intubation</article-title>
<source>Anaesth Intensive Care</source> <year>2008</year>
<volume>36</volume>
<issue>6</issue>
<fpage>870</fpage>
<lpage>4</lpage>
<comment>https://doi.org/10.1177/0310057X0803600620</comment>
</element-citation>
</ref>
<ref id="ref40">
<label>40</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Amundson</surname>
<given-names>AW</given-names>
</name>
<name>
<surname>Weingarten</surname>
<given-names>TN</given-names>
</name>
</person-group> 
<article-title>Traumatic GlideScope<sup>&#x00AE;</sup> video laryngoscopy resulting in perforation of the soft palate</article-title>
<source>Can J Anesth</source> <year>2013 Feb</year> <volume>60</volume>
<issue>2</issue>
<fpage>210</fpage>
<lpage>1</lpage>
<comment>https://doi.org/10.1007/s12630-012-9824-3</comment>
</element-citation>
</ref>
<ref id="ref41">
<label>41</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Pham</surname>
<given-names>Q</given-names>
</name>
<name>
<surname>Lentner</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Hu</surname>
<given-names>A</given-names>
</name>
</person-group> 
<article-title>Soft palate injuries during orotracheal intubation with the videolaryngoscope</article-title>
<source>Ann Otol Rhinol Laryngol</source> <year>2017 Feb</year> <volume>126</volume>
<issue>2</issue>
<fpage>132</fpage>
<lpage>7</lpage>
<comment>https://doi.org/10.1177/0003489416678008</comment>
</element-citation>
</ref>
<ref id="ref42">
<label>42</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Reynolds</surname>
<given-names>EC</given-names>
</name>
<name>
<surname>Crowther</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Corbett</surname>
<given-names>L</given-names>
</name>
<name>
<surname>Cominos</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Thomas</surname>
<given-names>V</given-names>
</name>
<name>
<surname>Cook</surname>
<given-names>TM</given-names>
</name> <etal/>
</person-group> 
<article-title>Improving laryngoscopy technique and success with the C-MAC<sup>&#x00AE;</sup> D blade: development and dissemination of the &#x201C;bath C-MAC D blade guide.&#x201D;</article-title>
<source>Br J Anaesth</source> <year>2020 Jul</year> <volume>125</volume>
<issue>1</issue>
<fpage>e162</fpage>
<lpage>4</lpage>
<comment>https://doi.org/10.1016/j.bja.2019.12.024</comment>
</element-citation>
</ref>
<ref id="ref43">
<label>43</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Penketh</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Kelly</surname>
<given-names>FE</given-names>
</name>
<name>
<surname>Cook</surname>
<given-names>TM</given-names>
</name>
</person-group> 
<article-title>Use of videolaryngoscopy as the first option for all tracheal intubations: technical benefits and a simplified algorithm for airway management</article-title>
<source>Br J Anaesth</source> <year>2023 Apr</year> <volume>130</volume>
<issue>4</issue>
<fpage>e425</fpage>
<lpage>6</lpage>
<comment>https://doi.org/10.1016/j.bja.2022.12.023</comment>
</element-citation>
</ref>
<ref id="ref44">
<label>44</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>De Jong</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Sfara</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Pouzeratte</surname>
<given-names>Y</given-names>
</name>
<name>
<surname>Pensier</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Rolle</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Chanques</surname>
<given-names>G</given-names>
</name> <etal/>
</person-group> 
<article-title>Videolaryngoscopy as a first-intention technique for tracheal intubation in unselected surgical patients: a before and after observational study</article-title>
<source>Br J Anaesth</source> <year>2022 Oct</year> <volume>129</volume>
<issue>4</issue>
<fpage>624</fpage>
<lpage>34</lpage>
<comment>https://doi.org/10.1016/j.bja.2022.05.030</comment>
</element-citation>
</ref>
<ref id="ref45">
<label>45</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Hansel</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Rogers</surname>
<given-names>AM</given-names>
</name>
<name>
<surname>Lewis</surname>
<given-names>SR</given-names>
</name>
<name>
<surname>Cook</surname>
<given-names>TM</given-names>
</name>
<name>
<surname>Smith</surname>
<given-names>AF</given-names>
</name>
</person-group> 
<article-title>Videolaryngoscopy versus direct laryngoscopy for adults undergoing tracheal intubation</article-title>
<source>Cochrane Database Syst Rev</source> <year>2022 Apr</year> <volume>4</volume>
<issue>4</issue>
<fpage>CD011136</fpage>
<comment>https://doi.org/10.1002/14651858.CD011136.pub3</comment>
</element-citation>
</ref>
<ref id="ref46">
<label>46</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Arici</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Karaman</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Dog&#x030C;ru</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Karaman</surname>
<given-names>T</given-names>
</name>
<name>
<surname>Tapar</surname>
<given-names>H</given-names>
</name>
<name>
<surname>&#x00D6;zsoy</surname>
<given-names>AZ</given-names>
</name> <etal/>
</person-group> 
<article-title>The McGrath series 5 video laryngoscope versus the Macintosh laryngoscope: a randomized trial in obstetric patients</article-title>
<source>Turk J Med Sci</source> <year>2014 Jan</year> <volume>44</volume>
<issue>3</issue>
<fpage>387</fpage>
<lpage>92</lpage>
<comment>https://doi.org/10.3906/sag-1306-71</comment>
</element-citation>
</ref>
<ref id="ref47">
<label>47</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Amini</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Shakib</surname>
<given-names>M</given-names>
</name>
</person-group> 
<article-title>Hemodynamic changes following endotracheal intubation in patients undergoing cesarean section with general anesthesia: application of glidescope<sup>&#x00AE;</sup> videolaryngoscope versus direct laryngoscope</article-title>
<source>Anesthesiol Pain Med</source> <year>2015</year>
<volume>5</volume>
<issue>2</issue>
<fpage>21836</fpage>
<comment>https://doi.org/10.5812/aapm.21836</comment>
</element-citation>
</ref>
<ref id="ref48">
<label>48</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Blajic</surname>
<given-names>I</given-names>
</name>
<name>
<surname>Hodzovic</surname>
<given-names>I</given-names>
</name>
<name>
<surname>Lucovnik</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Mekis</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Novak-Jankovic</surname>
<given-names>V</given-names>
</name>
<name>
<surname>Stopar Pintaric</surname>
<given-names>T</given-names>
</name>
</person-group> 
<article-title>A randomised comparison of C-MAC<sup>TM</sup> and king vision<sup>&#x00AE;</sup> videolaryngoscopes with direct laryngoscopy in 180 obstetric patients</article-title>
<source>Int J Obstet Anesth</source> <year>2019 Aug</year> <volume>39</volume>
<fpage>35</fpage>
<lpage>41</lpage>
<comment>https://doi.org/10.1016/j.ijoa.2018.12.008</comment>
</element-citation>
</ref>
<ref id="ref49">
<label>49</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Howle</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Onwochei</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Harrison</surname>
<given-names>SL</given-names>
</name>
<name>
<surname>Desai</surname>
<given-names>N</given-names>
</name>
</person-group> 
<article-title>Comparison of videolaryngoscopy and direct laryngoscopy for tracheal intubation in obstetrics: a mixed-methods systematic review and meta-analysis</article-title>
<source>Can J Anaesth</source> <year>2021 Apr</year> <volume>68</volume>
<issue>4</issue>
<fpage>546</fpage>
<lpage>65</lpage>
<comment>https://doi.org/10.1007/s12630-020-01908-w</comment>
</element-citation>
</ref>
<ref id="ref50">
<label>50</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Aziz</surname>
<given-names>MF</given-names>
</name>
<name>
<surname>Kim</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Mako</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Hand</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Brambrink</surname>
<given-names>AM</given-names>
</name>
</person-group> 
<article-title>A retrospective study of the performance of video laryngoscopy in an obstetric unit</article-title>
<source>Anesth Analg</source> <year>2012 Oct</year> <volume>115</volume>
<issue>4</issue>
<fpage>904</fpage>
<lpage>6</lpage>
<comment>https://doi.org/10.1213/ANE.0b013e3182642130</comment>
</element-citation>
</ref>
<ref id="ref51">
<label>51</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mclenachan</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Alexander</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Theodosiou</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Zhang</surname>
<given-names>C</given-names>
</name>
<name>
<surname>McNarry</surname>
<given-names>A</given-names>
</name>
</person-group> 
<article-title>McGrath MAC videolaryngoscope use in a tertiary obstetric unit</article-title>
<source>Trends Anaesth Crit Care</source> <year>2020 Feb</year>
<volume>30</volume>
<fpage>e106</fpage>
<comment>https://doi.org/10.1016/j.tacc.2019.12.262</comment>
</element-citation>
</ref>
<ref id="ref52">
<label>52</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Browning</surname>
<given-names>RM</given-names>
</name>
<name>
<surname>Rucklidge</surname>
<given-names>MWM</given-names>
</name>
</person-group> 
<article-title>Tracheal intubation using the Pentax Airway Scope videolaryngoscope following failed direct laryngoscopy in a morbidly obese parturient</article-title>
<source>Int J Obstet Anesth</source> <year>2011 Apr</year> <volume>20</volume>
<issue>2</issue>
<fpage>200</fpage>
<lpage>1</lpage>
<comment>https://doi.org/10.1016/j.ijoa.2010.12.008</comment>
</element-citation>
</ref>
<ref id="ref53">
<label>53</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Mustapha</surname>
<given-names>B</given-names>
</name>
<name>
<surname>Chkoura</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Elhassani</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Ahtil</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Azendour</surname>
<given-names>H</given-names>
</name>
<name>
<surname>Kamili</surname>
<given-names>ND</given-names>
</name>
</person-group> 
<article-title>Difficult intubation in a parturient with syringomyelia and Arnold-Chiari malformation: use of airtraq laryngoscope</article-title>
<source>Saudi J Anaesth</source> <year>2011 Oct</year> <volume>5</volume>
<issue>4</issue>
<fpage>419</fpage>
<lpage>22</lpage>
<comment>https://doi.org/10.4103/1658-354X.87274</comment>
</element-citation>
</ref>
<ref id="ref54">
<label>54</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Dhonneur</surname>
<given-names>G</given-names>
</name>
<name>
<surname>Ndoko</surname>
<given-names>S</given-names>
</name>
<name>
<surname>Amathieu</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Housseini</surname>
<given-names>L el</given-names>
</name>
<name>
<surname>Poncelet</surname>
<given-names>C</given-names>
</name>
<name>
<surname>Tual</surname>
<given-names>L</given-names>
</name>
</person-group> 
<article-title>Tracheal intubation using the Airtraq<sup>&#x00AE;</sup> in morbid obese patients undergoing emergency cesarean delivery</article-title>
<source>Anesthesiology</source> <year>2007 Mar</year> <volume>106</volume>
<issue>3</issue>
<fpage>629</fpage>
<lpage>30</lpage>
<comment>https://doi.org/10.1097/00000542-200703000-00027</comment>
</element-citation>
</ref>
<ref id="ref55">
<label>55</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ni</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Luo</surname>
<given-names>L</given-names>
</name>
<name>
<surname>Wu</surname>
<given-names>L</given-names>
</name>
<name>
<surname>Luo</surname>
<given-names>D</given-names>
</name>
</person-group> 
<article-title>The Airtraq<sup>TM</sup> laryngoscope as a first choice for parturients with an expected difficult airway</article-title>
<source>Int J Obstet Anesth</source> <year>2014 Feb</year> <volume>23</volume>
<issue>1</issue>
<fpage>94</fpage>
<lpage>5</lpage>
<comment>https://doi.org/10.1016/j.ijoa.2013.08.014</comment>
</element-citation>
</ref>
<ref id="ref56">
<label>56</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Salman</surname>
<given-names>MM</given-names>
</name>
<name>
<surname>Goetze</surname>
<given-names>N</given-names>
</name>
<name>
<surname>Badrinath</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Shah</surname>
<given-names>M</given-names>
</name>
</person-group> 
<article-title>The videolaryngoscope as a first-line intubation device in women with hypertensive disease of pregnancy</article-title>
<source>Int J Obstet Anesth</source> <year>2018 Feb</year> <volume>33</volume>
<fpage>87</fpage>
<lpage>8</lpage>
<comment>https://doi.org/10.1016/j.ijoa.2017.07.005</comment>
</element-citation>
</ref>
<ref id="ref57">
<label>57</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Apfelbaum</surname>
<given-names>JL</given-names>
</name>
<name>
<surname>Hagberg</surname>
<given-names>CA</given-names>
</name>
<name>
<surname>Connis</surname>
<given-names>RT</given-names>
</name>
<name>
<surname>Abdelmalak</surname>
<given-names>BB</given-names>
</name>
<name>
<surname>Agarkar</surname>
<given-names>M</given-names>
</name>
<name>
<surname>Dutton</surname>
<given-names>RP</given-names>
</name> <etal/>
</person-group> 
<article-title>2022 American society of anesthesiologists practice guidelines for management of the difficult airway</article-title>
<source>Anesthesiology</source> <year>2022 Jan</year> <volume>136</volume>
<issue>1</issue>
<fpage>31</fpage>
<lpage>81</lpage>
<comment>https://doi.org/10.1097/ALN.0000000000004002</comment>
</element-citation>
</ref>
<ref id="ref58">
<label>58</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ramkumar</surname>
<given-names>V</given-names>
</name>
<name>
<surname>Dinesh</surname>
<given-names>E</given-names>
</name>
<name>
<surname>Shetty</surname>
<given-names>SR</given-names>
</name>
<name>
<surname>Shah</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Kundra</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Das</surname>
<given-names>S</given-names>
</name> <etal/>
</person-group> 
<article-title>All India Difficult Airway Association 2016 guidelines for the management of unanticipated difficult tracheal intubation in obstetrics</article-title>
<source>Indian J Anaesth</source> <year>2016 Dec</year> <volume>60</volume>
<issue>12</issue>
<fpage>899</fpage>
<lpage>905</lpage>
<comment>https://doi.org/10.4103/0019-5049.195482</comment>
</element-citation>
</ref>
<ref id="ref59">
<label>59</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Aziz</surname>
<given-names>MF</given-names>
</name>
<name>
<surname>Brambrink</surname>
<given-names>AM</given-names>
</name>
<name>
<surname>Healy</surname>
<given-names>DW</given-names>
</name>
<name>
<surname>Willett</surname>
<given-names>AW</given-names>
</name>
<name>
<surname>Shanks</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Tremper</surname>
<given-names>T</given-names>
</name> <etal/>
</person-group> 
<article-title>Success of intubation rescue techniques after failed direct laryngoscopy in adults: a retrospective comparative analysis from the multicenter perioperative outcomes group</article-title>
<source>Anesthesiology</source> <year>2016 Oct</year> <volume>125</volume>
<issue>4</issue>
<fpage>656</fpage>
<lpage>66</lpage>
<comment>https://doi.org/10.1097/ALN.0000000000001267</comment>
</element-citation>
</ref>
<ref id="ref60">
<label>60</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Paolini</surname>
<given-names>JB</given-names>
</name>
<name>
<surname>Donati</surname>
<given-names>F</given-names>
</name>
<name>
<surname>Drolet</surname>
<given-names>P</given-names>
</name>
</person-group> 
<article-title>Review article: video-laryngoscopy: another tool for difficult intubation or a new paradigm in airway management?</article-title>
<source>Can J Anaesth</source> <year>2013 Feb</year> <volume>60</volume>
<issue>2</issue>
<fpage>184</fpage>
<lpage>91</lpage>
<comment>https://doi.org/10.1007/s12630-012-9859-5</comment>
</element-citation>
</ref>
<ref id="ref61">
<label>61</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Maharaj</surname>
<given-names>CH</given-names>
</name>
<name>
<surname>Costello</surname>
<given-names>JF</given-names>
</name>
<name>
<surname>Higgins</surname>
<given-names>BD</given-names>
</name>
<name>
<surname>Harte</surname>
<given-names>BH</given-names>
</name>
<name>
<surname>Laffey</surname>
<given-names>JG</given-names>
</name>
</person-group> 
<article-title>Learning and performance of tracheal intubation by novice personnel: a comparison of the Airtraq<sup>&#x00AE;</sup> and Macintosh laryngoscope</article-title>
<source>Anaesthesia</source> <year>2006 Jul</year> <volume>61</volume>
<issue>7</issue>
<fpage>671</fpage>
<lpage>7</lpage>
<comment>https://doi.org/10.1111/j.1365-2044.2006.04653.x</comment>
</element-citation>
</ref>
<ref id="ref62">
<label>62</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Cortellazzi</surname>
<given-names>P</given-names>
</name>
<name>
<surname>Caldiroli</surname>
<given-names>D</given-names>
</name>
<name>
<surname>Byrne</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Sommariva</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Orena</surname>
<given-names>EF</given-names>
</name>
<name>
<surname>Tramacere</surname>
<given-names>I</given-names>
</name>
</person-group> 
<article-title>Defining and developing expertise in tracheal intubation using a GlideScope<sup>&#x00AE;</sup> for anaesthetists with expertise in Macintosh direct laryngoscopy: an in-vivo longitudinal study</article-title>
<source>Anaesthesia</source> <year>2015 Mar</year> <volume>70</volume>
<issue>3</issue>
<fpage>290</fpage>
<lpage>5</lpage>
<comment>https://doi.org/10.1111/anae.12878</comment>
</element-citation>
</ref>
<ref id="ref63">
<label>63</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Ghotbaldinian</surname>
<given-names>E</given-names>
</name>
<name>
<surname>Dehdari</surname>
<given-names>N</given-names>
</name>
<name>
<surname>&#x00C5;keson</surname>
<given-names>J</given-names>
</name>
</person-group> 
<article-title>Maintenance of basic endotracheal intubation skills with direct or video-assisted laryngoscopy: a randomized crossover follow-up study in inexperienced operators</article-title>
<source>AEM Educ Train</source> <year>2021 Oct</year> <volume>5</volume>
<issue>4</issue>
<fpage>e10655</fpage>
<comment>https://doi.org/10.1002/aet2.10655</comment>
</element-citation>
</ref>
<ref id="ref64">
<label>64</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Sakles</surname>
<given-names>JC</given-names>
</name>
<name>
<surname>Mosier</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Patanwala</surname>
<given-names>AE</given-names>
</name>
<name>
<surname>Dicken</surname>
<given-names>J</given-names>
</name>
</person-group> 
<article-title>Learning curves for direct laryngoscopy and GlideScope<sup>&#x00AE;</sup> video laryngoscopy in an emergency medicine residency</article-title>
<source>West J Emerg Med</source> <year>2014</year>
<volume>15</volume>
<issue>7</issue>
<fpage>930</fpage>
<lpage>7</lpage>
<comment>https://doi.org/10.5811/westjem.2014.9.23691</comment>
</element-citation>
</ref>
<ref id="ref65">
<label>65</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Kelly</surname>
<given-names>FE</given-names>
</name>
<name>
<surname>Cook</surname>
<given-names>TM</given-names>
</name>
</person-group> 
<article-title>Seeing is believing: getting the best out of videolaryngoscopy</article-title>
<source>Br J Anaesth</source> <year>2016 Sep</year> <volume>117</volume>
<fpage>i9</fpage>
<lpage>13</lpage>
<comment>https://doi.org/10.1093/bja/aew052</comment>
</element-citation>
</ref>
<ref id="ref66">
<label>66</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Lambert</surname>
<given-names>CT</given-names>
</name>
<name>
<surname>John</surname>
<given-names>SC</given-names>
</name>
<name>
<surname>John</surname>
<given-names>AV</given-names>
</name>
</person-group> 
<article-title>Development and performance testing of the low-cost, 3D-printed, smartphone-compatible &#x201C;tansen videolaryngoscope&#x201D; vs. pentax-AWS videolaryngoscope vs. direct macintosh laryngoscope: a manikin study</article-title>
<source>Eur J Anaesthesiol</source> <year>2020 Nov</year> <volume>37</volume>
<issue>11</issue>
<fpage>992</fpage>
<lpage>8</lpage>
<comment>https://doi.org/10.1097/EJA.0000000000001264</comment>
</element-citation>
</ref>
<ref id="ref67">
<label>67</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Saoraya</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Musikatavorn</surname>
<given-names>K</given-names>
</name>
<name>
<surname>Sereeyotin</surname>
<given-names>J</given-names>
</name>
</person-group> 
<article-title>Low-cost videolaryngoscope in response to COVID-19 pandemic</article-title>
<source>Western J Emerg Med</source> <year>2020</year>
<volume>21</volume>
<issue>4</issue>
<fpage>817</fpage>
<lpage>8</lpage>
<comment>https://doi.org/10.5811/westjem.2020.5.47831</comment>
</element-citation>
</ref>
<ref id="ref68">
<label>68</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>Zhang</surname>
<given-names>J</given-names>
</name>
<name>
<surname>Jiang</surname>
<given-names>W</given-names>
</name>
<name>
<surname>Urdaneta</surname>
<given-names>F</given-names>
</name>
</person-group> 
<article-title>Economic analysis of the use of video laryngoscopy versus direct laryngoscopy in the surgical setting</article-title>
<source>J Comp Eff Res</source> <year>2021 Jul</year> <volume>10</volume>
<issue>10</issue>
<fpage>831</fpage>
<lpage>44</lpage>
<comment>https://doi.org/10.2217/cer-2021-0068</comment>
</element-citation>
</ref>
<ref id="ref69">
<label>69</label>
<element-citation citation-type="journal">
<person-group person-group-type="author">
<name>
<surname>G&#x00F3;mez-R&#x00ED;os</surname>
<given-names>M&#x00C1;</given-names>
</name>
<name>
<surname>Casans-Franc&#x00E9;s</surname>
<given-names>R</given-names>
</name>
<name>
<surname>Abad-Gurumeta</surname>
<given-names>A</given-names>
</name>
<name>
<surname>Esquinas</surname>
<given-names>AM</given-names>
</name>
</person-group> 
<article-title>The role of videolaryngoscopy in airway management of COVID-19 patients</article-title>
<source>Anaesthesiol Intensive Ther</source> <year>2020</year>
<volume>52</volume>
<issue>4</issue>
<fpage>344</fpage>
<lpage>5</lpage>
<comment>https://doi.org/10.5114/ait.2020.99504</comment>
</element-citation>
</ref>
</ref-list>  
<fn-group>
<fn fn-type="conflict">
<p>Conflicts of interest:  Author declares no conflicts of interest.</p>
</fn>
<fn fn-type="supported-by">
<p>Funding:  This work was supported by the Slovenian Research Agency (grant number P3-0043) and tertiary funding from the Clinical Department of Anaesthesiology and Intensive Therapy, University Clinical Centre (Ljubljana, Slovenia) (grant number TP 20180063).</p>
</fn>
</fn-group></back></article>